appendix1‑7
30
Velocity monitor select
This parameter is used for monitoring signals by the analog monitor card (optional).
This parameter switches between the output modes of the velocity monitor.
0: Velocity monitor
1: Velocity monitor AC
0
1
0
Min:
Max:
Initial:
Unit:
VelMonSel
Dec
31
Velocity monitor gain
This parameter is used for monitoring signals by the analog monitor card (optional).
Specifies the monitoring gain scale factor of the velocity monitor.
If the specified scaling value is 'n', then:
+/‑3.07V vs +/‑2^n
2^n will result in an amplitude of +/‑ 3.07V on the velocity monitor
The maximum amplitude voltage is +/‑4.80V.
8
24
8
Min:
Max:
Initial:
Unit:
VelMonGain
Dec
32
Analog monitor select #1
This parameter is used for monitoring signals by the analog monitor card (optional).
Selects item to be output to the analog monitor #1. Specify the paramter monitor number to be observed
0
399
372
Min:
Max:
Initial:
Unit:
A̲Mon1Sel
Dec
33
Analog monitor gain #1
This parameter is used for monitoring signals by the analog monitor card (optional).
Specifies the monitoring gain scale factor of the analog monitor #1.
If the specified scaling value is 'n', then:
+/‑3.07V vs +/‑2^n
2^n will result in an amplitude of +/‑ 3.07V on the velocity monitor
The maximum amplitude voltage is +/‑4.80V.
8
24
8
Min:
Max:
Initial:
Unit:
A̲Mon1Gain
Dec
34
Analog monitor select #2
This parameter is used for monitoring signals by the analog monitor card (optional).
Selects item to be output to the analog monitor #2. Specify the paramter monitor number to be observed
0
399
378
Min:
Max:
Initial:
Unit:
A̲Mon2Sel
Dec
TI 71M01D06‑01E 2nd Edition : 2007.01.10‑00