vii
IM 71M02D04-01E 10th Edition: 2012.12.01
・
A part of machine parameters overwrites the related parameters when the power is
recycled, if those parameters are changed. “10.0x (Data Sum Error)” may rarely occur
in case that the control power supply is terminated before LED for RDY signal is
lighted when the power is recycled. If this error occurs, restore user data, which was
backed up beforehand, after initialization of user parameters (Backed up parameter
values are set).
・
Make sure not to terminate control power supply while All-Reset function is in
execution. All-Reset needs more 5 (five) seconds for the completion. “10.0x (Data
Sum Error)” may occur in case that the control power supply is terminated in this
while. Execute All-Reset again if the error occurs.
・
Utility software includes several functions, which recycle AC main power automatically.
“10.0x (Data Sum Error)” may rarely occur in case that the control power supply is
terminated before LED for RDY signal is lighted when the power is recycled. If this
error occurs, restore user data, which was backed up beforehand, after initialization of
user parameters (Backed up parameter values are set).
・
If you turn off the power after the occurrence of overload error, please turn on the
power after more than 10min.
If this error occurs again, please review the operating conditions.