PROGRAM OPERATING FUNCTION
■
Overview of Program Setting
To operate the controller using a program, first create the program. The UP150 have one program pattern.
Program operation is based on a program pattern consisting of up to 16 segments as shown in the figure below. To
create a program pattern, set the target setpoint to be rached and segment time for each segment. Tow PV events
and/or two time event can be set for a program.
0
°
C
50
°
C
EOFF
EON
100
°
C
30
Min.
30
Min.
20
Min.
30
Min.
30
Min.
30
Min.
35
Min.
30
Min.
Segment No.
Destination target value (SP)
Segment time (TM) (Hour; Min.)
EON1
EOF1
AL1
A1
HY1
EON2
EOF2
AL2
A2
HY2
0:30
1:20
1(PV high limit)
110
°
C
10
°
C
Time event 1
(EV1=1)
PV event 1
(EV1=0)
Time event 2
(EV2=1)
PV event 2
(EV2=0)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
50
°
C 50
°
C 100
°
C 100
°
C 50
°
C 50
°
C
0
°
C
0:30
0:30
0:20
0:30
0:30
0:35
0:30
100%
0%
PV high limit (110
°
C)
0:30 (EVENT ON)
1:20 (EVENT OFF)
Program Pattern Settings