3-14
<Toc>
<3. Programming>
IM 05E01D02-41E
1st Edition : May 31,2000-00
Parameter
Symbol
Name of
Parameter
Setting Range and Description
Initial Value
Target Item
in CD-ROM
User
Setting
0.0% of PV
input range
0.0% of PV
input range
0.0% of PV
input range
0.0% of PV
input range
0.0% of PV
input range
0.0 to 100.0% of PV input range
0.0 to 100.0% of PV input range
0.0 to 100.0% of PV input range
0.0 to 100.0% of PV input range
0.0 to 100.0% of PV input range
0.0% of PV
input range
0.0 to 100.0% of PV input range
0.0% of PV
input range
0.0 to 100.0% of PV input range
0.0% of PV
input range
0.0 to 100.0% of PV input range
0.0% of PV
input range
0.0 to 100.0% of PV input range
Segment-2
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-3
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-4
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-5
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-6
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-7
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-8
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-9
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-10
segment time
OFF, 0.00 to 99.59 (hour and minute or minute and second)
Ramp setting: OFF, 0.0 to 100.0% of PV input range span
(1 hr or 1 min.)
Segment-2
target setpoint
OFF
Segment-3
target setpoint
OFF
Segment-4
target setpoint
OFF
Segment-5
target setpoint
OFF
Ref.5.1(1)
Segment-6
target setpoint
OFF
Segment-7
target setpoint
OFF
Segment-8
target setpoint
OFF
Segment-9
target setpoint
OFF
Segment-10
target setpoint
OFF
Junction code
0: End of resetting
1: End of hold
2: Pattern 1 startup
3: Pattern 2 startup
0
(2.SP2)
(2.TM2)
(2.TM3)
(2.TM4)
(2.TM5)
(2.TM6)
(2.TM7)
(2.TM8)
(2.TM9)
(2.SPA)
(2.TMA)
(2.JC)
(2.SP3)
(2.SP4)
(2.SP5)
(2.SP6)
(2.SP7)
(2.SP8)
(2.SP9)
Summary of Contents for UP350
Page 2: ...Blank Page ...
Page 52: ...Blank Page ...
Page 62: ...Blank Page ...
Page 72: ...Blank Page ...
Page 94: ...Blank Page ...
Page 96: ...Blank Page ...