<Toc>
<4. Operations>
4-9
IM 05E01D02-41E
1st Edition : May 31,2000-00
4.7
Executing “Advance” Function
The following operating procedure advances a segment or segments during program
operation.
1.
Bring the operating display into view
(appears at power-on).
P V
SP
PVE1
TME
PVE2
PRG1
HLD
PRG2
SET/ENT
1
PRG
2
PRG
RESET
PRG1 lamp
ON.
Displays PV.
2.
Press the
SET/ENT
key for more than 3 seconds
to call up the menu “OP.PA”.
P V
SP
PVE1
TME
PVE2
PRG1
HLD
PRG2
SET/ENT
1
PRG
2
PRG
RESET
Displays
menu “OP.PA”.
3.
Press the
SET/ENT
key twice to display the
parameter “ADV”.
P V
SP
PVE1
TME
PVE2
PRG1
HLD
PRG2
SET/ENT
1
PRG
2
PRG
RESET
Displays
parameter
“ADV”.
4.
Press the
key once to display “1”.
P V
SP
PVE1
TME
PVE2
PRG1
HLD
PRG2
SET/ENT
1
PRG
2
PRG
RESET
Blinks during
change.
5.
Press the
SET/ENT
key once to register the
setpoint.
P V
SP
PVE1
TME
PVE2
PRG1
HLD
PRG2
SET/ENT
1
PRG
2
PRG
RESET
The controller automatically returns to the
display shown at power-on (figure below).
P V
SP
PVE1
TME
PVE2
PRG1
HLD
PRG2
SET/ENT
1
PRG
2
PRG
RESET
Displays the
setpoint of the
next segment.