5-6
<Toc>
<5. Troubleshooting and Maintenance>
IM 05E01D02-41E
1st Edition : May 31,2000-00
5.2.4
Replacing Parts with a Limited Service Life
The following UP350 parts have a limited service life.
The service life given in the table assume that the controller is used under normal operating
conditions.
Part
Aluminum electrolytic condenser
About 10 years (rated)
Service life
Alarm output relays
About 100,000 more ON-OFF operations or with resistance load
EEPROM
About 100,000 times of writings
Control output relays
About 100,000 more ON-OFF operations or with resistance load
If any of these parts, except control output relays, cause a controller failure due to deterio-
ration, contact your dealer for replacement at your cost.
Control output relays can be replaced by yourself.
SEE ALSO
“5.2.5 Replacing Control Output Relays,” for how to replace the control output relays.