4-5
IM 04P02B01-01E
Common Operations for Setting Functions and Setup Guide
4
4.3
Menu Structure, Settings, and List of Default
Values
Operation Menus Using the FUNC Key (Operation Mode)
Below are the items that are operated using the
FUNC
key. Information indicated inside
the parentheses is references.
: Use the
key.
key.
Message 1
Message 2
Message 3
Message 4
Message 5
Alarm
Password
Message
Start/Stop
Reset
Reset
Pen exchange = End
Ribbon exchange = End
List Start/List Stop
Setup Start/Setup Stop
Manual Start/Manual Stop
: Use the
Alarm ACK
Message
Buffer clear
Keylock
Periodic
Print out
Pen exchange
Ribbon exchange
(section 3.12)
(section 9.1)
(section 3.10)
(sections 3.7, 3.8)
(sections 3.9, 3.10)
(section 3.13)
(section 3.11)
(section 3.3)
(Pen model)
(Dot model)
(section 3.4)
Math
key
FUNC
Alarm ACK
Alarm output release operation. This operation is valid only when the alarm indication or
relay output is set to hold operation.
Math (Models with the Computation Function (/M1 Option))
Starts/stops the computation.
Print out
Starts/Stops the manual printout or setting printout (List or Setup).
Message
Prints messages.
Buffer clear
Clears the data waiting to be printed in the alarm printout buffer or the message printout
buffer.
Keylock
Activates or releases the key lock. This operation is possible only when the use of the
key lock function is enabled.
Periodic
Resets the computed value when printing of the report data (average, etc.) is specified in
periodic printout.