Using the Battery Resistance Meter program, one can check the total internal resistance of the
battery, along with the highest and lowest internal resistance, and internal resistance of each
individual cell. A balance cable must be connected to use this feature.
LISTING OF ERROR MESSAGES
BATTERY RESISTANCE METER
Select the "BATT RESISTANCE" program from the Battery Program
menu, and press ENTER button.
The resistance of each cell will be displayed.
Pressing the
+/-
buttons, will toggle between the previous screen
and this screen which shows the battery total resistance, and highest
and lowest cell resistance.
In case of an error, the charger will make a warning tones and one of the following error messages
will appear on the LCD display.
Battery polarity is reversed
Connection to the battery has been interrupted.
Battery is incorrectly connected. Check connection.
Balance cable is incorrectly connected. Check connection.
Input DC voltage is under 11 V.
Input DC voltage is over 18 V.
Voltage of cell(s) in the battery is too low.
Voltage of cell(s) in the battery is too high.
Voltage of cell(s) in the battery is invalid.
Number of cells is not correct.
Internal temperature of the charger is too high.
External temperature sensor for the battery is too high.
The battery capacity has reached the set maximum capacity limit.
The charging time has reached the set maximum charging time.
The battery voltage is higher than the set maximum voltage,
when charging in balance charging mode.