background image

7

Pulse interval: longer

8

Tool output : lower

9

Pulse interval : shorter 

Never adjust fully at max or min, always at least 60 degrees from min and max.

Using the Programming Console PC-1

​Connect the PC-1 with cable CC-1 to the tool.

Programming Console PC-1

1   Mounting hole

 

2   Display screen

Displays tightening result, setting item and set value

3   Function key

Switching of tightening screen, setting screen and or of display screen

4   Numeric key

Enter the set value

5   CAN key

Return to the previous screen

6   ENT key

Determine items and input value

7   Up, down, left and right key

Move the selection of setting items up and down

8   PRC05 connector

Cable connector 

​Start Screen

​After connecting the PC-1 with cable CC-1 to the YZ-T tool it will take approx. 5 seconds for the PC-1 to start up, please see below following screens:

Summary of Contents for YZ-T800A

Page 1: ...YZ T800A MANUAL EN www rami yokota com...

Page 2: ...to our website Make sure that during operation of the tool no projectiles can be generated this can be dangerous and may cause injuries Make sure that the work piece is securely fixed Make sure that t...

Page 3: ...t in short circuit of the terminals of the battery pack and fire Do not expose battery cartridge to water or rain A battery short can cause large current flow overheating possibly burns and even a bre...

Page 4: ...s too low 10 Value too low 11 Number of impulses too high 12 Cycle OK The torque reached in the joint is depending on 3 settings The motor speed 1 Output value 2 Cut value 3 Tightening time 4 Value ri...

Page 5: ...s output with the relief valve mechanical adjustment on the impulse mechanism Always take off the battery when adjusting the torque output with the relief valve on the impulse mechanism Use the TF pin...

Page 6: ...sult setting item and set value 3 Function key Switching of tightening screen setting screen and or of display screen 4 Numeric key Enter the set value 5 CAN key Return to the previous screen 6 ENT ke...

Page 7: ...arameter or use CAN to cancel the input value Use Up and Down arrow to select the next parameter to be set Press NEXT key to enter the next page of parameters to be set or PREV to previous page By pre...

Page 8: ...o enter this function Result 20 the average on which the tool has shut off NUM 6 number of impulses including the impulses lower than start value 6 12 15 19 20 21 the value of each impulse If you have...

Page 9: ...value Switch value Cut value Max value 10 150 10 Switch value Value to switch motor speed from middle speed to high speed Switch value Cut value Max value 10 150 10 Cut value Shut off value as soon as...

Page 10: ...h speed a little higher Set the minimum and maximum number of impulses according the hardness of the application Set the start value and the switch value according the hardness of the application The...

Page 11: ...Over voltage Error Over current Error Abnormal pulse signal Memory Error Please send the tool for repair to an authorized service shop Extreme low environment temperature can show a wire breakage erro...

Page 12: ...pack Overheat alarm 3 Lighting Please wait until release LED lamp lights off 1 Low voltage error may operate when using a battery pack whose performance has deteriorated due to deterioration low temp...

Page 13: ...of warranty claims is no part of the warranty arrangements Also claims for loss of production and or other damages are excluded from this warranty Repairs under warranty can only be considered when t...

Page 14: ...www rami yokota com...

Reviews: