background image

12

6.8.2 PAS sensor sensitivity setting

SCN is the PAS sensor sensitivity setting. The adjustable range is: 2-9. 2 is the highest level sensitivity while 9 is the

lowest.

Press the

/

to select the parameter and press

to save the parameter setting and enter into 6.8.3 PAS

magnets number setting interface or long press

to return to the personalized parameter setting interface.

Figure 6-10 PAS sensor sensitivity setting interface

6.8.3 Number of pedal assist sensor magnets setting

PAS is the pedal

assist sensor magnets setting

. The adjustable range is: 5-31.

Press the

/

to select the parameter and press

to save the parameter setting and

to return to the

personalized parameter setting interface.

Figure 6-11 Pedal assist sensor magnets setting

Summary of Contents for YL90T-H

Page 1: ...Tianjin Yolin Technology Ltd Electric Bike Display User s Manual YL90T H...

Page 2: ...ETTING 7 6 2 RATED VOLTAGE SETTING 7 6 3 PAS LEVEL SETTING 8 6 3 1 PAS LEVEL RATIO VALUE SETTING 8 6 4 WHEEL DIAMETER SETTING 9 6 5 NUMBER OF SPEED SENSOR MAGNETS SETTING 9 6 6 SPEED LIMIT SETTING 10...

Page 3: ...9 WIRE CONNECTION DIAGRAM 19 9 1 STANDARD WIRE CONNECTION SEQUENCE 19 10 PRECAUTIONS 19 SCHEDULE 1 ERROR CODE DEFINITION 20 SCHEDULE 2 PEDAL ASSIST LEVEL DEFAULT RATIO VALUE 20...

Page 4: ...pecification 36V 48V 52V power supply Display rated current 15mA Display maximum current 30mA Shutdown leakage current 1uA Supplied current to the controller 50mA Operating temperature 20 60 Storage t...

Page 5: ...2 K5 K6 Figure 3 2 Physical picture of the 90T control button Figure 3 3 90T Front View Dimension Figure 3 4 90T Side View Dimension...

Page 6: ...and PAS parameter setting password setting controller current limit setting etc Factory default parameter recovery function 4 2 Functional areas Figure 4 1 YL90T functional area distribution interface...

Page 7: ...splay interface switching When the display is powered on it will show the Current Speed km h and Odometer km by default Short press to switch between Odometer km Trip Odometer km Maximum Speed km h an...

Page 8: ...display screen The walk boost mode can only be used when pushing the electric bicycle please do not use it while riding 5 4 Turning on off lights Press the to make the controller turn on the lights an...

Page 9: ...Error code display If there is a fault occurs in the electronic system of the electric bicycle the display will automatically show an error code see Schedule 1 for a detailed definition of the error c...

Page 10: ...g interface The following options are available on the personalized parameter setting interface 6 1 Metric and Imperial setting P1 is the metric and imperial setting 00 for metric and 01 for imperial...

Page 11: ...erface 6 3 1 PAS level ratio value setting To meet different requirements for users the speed of every level can be adjusted by setting the PAS level ratio value Please see the details from Schedule 2...

Page 12: ...g interface Figure 6 5 Wheel diameter setting interface 6 5 Number of speed sensor magnets setting P5 is the speed sensor magnet number setting The adjustable speed sensor magnet number range is 1 15...

Page 13: ...save the parameter setting and return to the personalized parameter setting interface Figure 6 7 Speed limit setting interface 6 7 Controller current Limit Setting P7 is the controller current limit s...

Page 14: ...sor direction setting run F is front direction and run b is opposite direction Press to enter the parameter changing state Press the to select the parameter and press to save the parameter setting and...

Page 15: ...gnets number setting interface or long press to return to the personalized parameter setting interface Figure 6 10 PAS sensor sensitivity setting interface 6 8 3 Number of pedal assist sensor magnets...

Page 16: ...able the walk boost and it can reach the max speed when using throttle Press the to select the HL Y and press to save the parameter setting and return to the personalized parameter setting interface P...

Page 17: ...speed Press the to select the parameter and press to save the parameter setting and to return to the personalized parameter setting interface Figure 6 13 Throttle level setting 6 10 Power on password...

Page 18: ...ameter setting interface Figure 6 14 Power on Password OFF interface Figure 6 15 Power on Password Activated interface In the password setting mode the adjustable digit will flash Press the to select...

Page 19: ...has not been used for a time The adjustable range is 1 60min 00 means no auto shutdown The factory default setting is 10 minutes Press to enter the parameter changing state Press the to select the par...

Page 20: ...ce and keep the speed at 0 press and hold and simultaneously for 2s to enter the restore factory default setting interface Pressing to toggle to dEF Y Then after pressing to confirm the display will s...

Page 21: ...set process Figure 7 2 Trip Odometer Reset Interface 8 Quality Assurance and Warranty 8 1 Warranty info Yolin will offer a limited warranty for any failure caused by the product defects under normal u...

Page 22: ...X Display data transmit wire Some models are equipped with waterproof connectors and the color inside wires can not be seen 10 Precautions Pay attention to all the general operating when using the pro...

Page 23: ...ilure E022 Throttle failure E025 Brake failure E023 Motor phase failure E030 Communication failure breakdown Schedule 2 Pedal assist level default ratio value Level Level selection 1 2 3 4 5 6 7 8 9 0...

Reviews: