background image

ZC179 RFID module manual 

 

 

To remove cards: Place the card on antenna, press module’s button. If 

this card has already been added to ZC179 module, the relay will pop 3 

times. On the contrary, relay will pop twice and add this card, if this 

card doesn’t exist in module’s memory. Please note that ZC179 module 

will go into insecurity mode, if user deletes all the cards from its 

memory. 

 

To remove all cards: Press module’s button before power on ZC179 module. 

The relay will pop 3 times, while all the card records will be deleted. 

 

To open the gate: Make sure the button is released. The relay will be 

closed for N seconds, once ZC179 module finds a valid card. For security 

reason, relay will only be closed for N seconds, if there is a valid card 

in antenna range. 

 

Relay states: Rotate state is defined when N equals to zero. In such state, 

the relay will flip once (ON or OFF), every time a valid card is found.You 

may set N to zero by releasing the button immediately, when setting up 

ZC179 module for the first time. 

 

4.

 

P

RODUCT DETAILS

 

 

RF parameters

 

Protocol ISO/IEC18000-Part2 

Carrier frequency 

125KHz 

tuning range 

25KHz 

date rate 

5.2KBps 

modulate mode 

OOK 

antenna type 

near field loop antenna 

antenna magnetic field 

H≤7.5A/m rms, H≥1.5A/m rms at 5cm 

antenna gain 

directivity(dB)=1.22    gain(dB)=1.17 

antenna impedance 

Z=

 

0.0017+0.6464i (Z

o

=50) 

Electric parameters 

operating temperature 

-20°~70°C 

operating humidity 

≤90% 

supply voltage 

DC12V±10% 

absolute maximum voltage  

DC20V 

maximum power consumption 

1W 

 

Reviews: