8. Programming limit positions
9. Removing limit positions
10. Programming the third limit position
4
To set the upper and lower limit position press the programming button P2 during the motor movement, it causes the work displacement.
Then you can precisely set the limit positions. Pressing the P2 button again motor will run continuously.
Press
programming
button P2.
Press
UP button.
Press
programming
button P2 again.
Upper limit position
Press
UP button.
Blind will make up/down
movement. Motor will
make a sound.
Blind will make up/down
movement. Motor will
make a sound.
Blind will make up/down
movement. Motor will make
a few short sounds
When the blind
reaches upper limit position
press STOP button.
Blind will make up/down
movement. Motor will
make a sound.
Blind will make up/down
movement. Motor will
make a sound.
Press STOP button
5 times at 0.5 sec
intervals to confirm
the upper limit position.
Press
STOP button
5 times at 0.5 sec
intervals to confirm
the lower
limit position.
Press
DOWN button.
Limit positions
has been
programmed.
Lower
limit position.
When the blind
reaches lower
limit position
press STOP button
Blind will make up/down
movement. Motor will
make a sound.
Blind will make up/down
movement. Motor will
make a sound.
Blind will make up/down
movement. Motor will make a few short
sounds
Limit positions
has been removed.
Press
programming
button P2
Press
programming
button P2 again.
Press
DOWN button.
1. After setting the upper and lower limit positions, it is possible to set the third position (favorite) between those positions.
2. Hold the STOP button for 3 seconds to set the blind in third limit position.
3. When the motor is in pulse mode, hold the STOP button for 3 seconds, blind reaches lower limit position, and then to the set third
position
Blind will make up/down
movement. Motor will
make a sound.
Blind will make up/down
movement. Motor will make
a few short sounds.
Favourite position
has been set.
Press
STOP button.
Press
STOP button.
Blind will
make up/down
movement.
Upper limit position
has been set.
Lower limit position
has been set.
An example of the third
limit position
Set the blind
in favourite position.
Press
programming
button P2.