background image

8. Programming limit positions

9. Removing limit positions

10. Programming the third limit position

4

To set the upper and lower limit position press the programming button P2 during the motor movement, it causes the work displacement. 

Then you can precisely set the limit positions. Pressing the P2 button again motor will run continuously.

Press

programming

button P2.

Press

UP button.

Press

programming

button P2 again.

Upper limit position

Press

UP button.

Blind will make up/down

movement. Motor will

make a sound.

Blind will make up/down

movement. Motor will

make a sound.

Blind will make up/down

movement. Motor will make 

a few short sounds

When the blind 

reaches upper limit position 

press STOP button.

Blind will make up/down

movement. Motor will

make a sound.

Blind will make up/down

movement. Motor will

make a sound.

Press STOP button

5 times at 0.5 sec

intervals to confirm

the upper limit position.

Press 

STOP button

5 times at 0.5 sec 

intervals to confirm 

the lower 

limit position.

Press

DOWN button.

Limit positions

has been 

programmed.

Lower

limit position.

When the blind

reaches lower

limit position

press STOP button

Blind will make up/down

movement. Motor will

make a sound.

Blind will make up/down

movement. Motor will

make a sound.

Blind will make up/down

movement. Motor will make a few short 

sounds

Limit positions

has been removed.

Press

programming

button P2

Press

programming

button P2 again.

Press

DOWN button.

1. After setting the upper and lower limit positions, it is possible to set the third position (favorite) between those positions.

2. Hold the STOP button for 3 seconds to set the blind in third limit position.

3. When the motor is in pulse mode, hold the STOP button for 3 seconds, blind reaches lower limit position, and then to the set third

position

Blind will make up/down

movement. Motor will 

make a sound.

Blind will make up/down

movement. Motor will make 

a few short sounds.

Favourite position

has been set.

Press

STOP button.

Press

STOP button.

Blind will

make up/down

movement.

Upper limit position

has been set.

Lower limit position

has been set.

An example of the third

limit position

Set the blind

in favourite position.

Press

programming

button P2.

Reviews: