PRODUCT DESCRIPTION
2.1
Introduction
The YCAA range of twin refrigerant circuit chillers/heat
pumps are designed to be located outside on the roof of
a building or at ground level.
The range includes the following models:
The following options are available:
Option
Description
Hydro Kit
The field mounted hydro kit comes complete
with all components for correct operation of a
liquid distribution circuit.
Remote
On/Off Kit
A field mounted control panel to provide
remote on/off control (only for user friendly
standard control).
Pressure
Gauge Kit
Factory fitted mechanical gauge kit for display
of unit operating parameters (only for user
friendly standard control).
Flow Switch
Kit
Field mounted flow switch for the evaporator
water circuit.
Spring
Isolators
Open spring isolator mounts with fixing holes,
supplied loose for field installation.
Condenser
Coil Protection
Copper fins, blue fins (pre-coated aluminium
condenser fins).
Condenser
Coil Guards
Painted galvanised steel wire guards mounted
on the exterior of the unit.
Integrated
System
Network (ISN)
Control
The ISN control offers Building Management
System (BMS) communication, leaving chilled
liquid temperature control, sequence control,
double setpoint, display and print of unit
operational and history data alarm history.
(Refer to Section 2.8 for further details)
Water filter
A field mounted water filter.
(09/03)
035B09012-100 Rev. 4
2
-
1
2
7
4
1
5
6
6
3
YCAA Models 60 - 150
HYDRO KIT (Optional)
6
3
7
9
8
YCAA Models 170 - 210
Models
Description
YCAA-B
(Standard Operation)
YCAA-B LN
(Low Noise Operation)
YCAA-B HT
(High Temperature Operation)
Water chiller charged with
refrigerant R407C
YCAA-H
(Standard Operation)
YCAA-H LN
(Low Noise Operation)
Water chiller/heat pump
charged with refrigerant R22
YCAA models 60 - 150 of all versions are available with either
user friendly standard control or optional York Integrated System
Network (ISN) control. YCAA models 170 - 210 are fitted with
York ISN control as standard.
Water/Glycol chiller charged
with refrigerant R407C
1 Compressor Compartment
3 Air Cooled Condenser 5 Cable Entry
7 Control Panel 9 Cooler
2 Power and Control Compartment
4 Cooling Fan
6 Lifting Points
8 Compressor
Summary of Contents for YCAA B 120
Page 2: ......
Page 16: ...This Page Left Intentionally Blank 09 03 2 6 035B09012 100 Rev 4 ...
Page 28: ...This Page Left Intentionally Blank 09 03 4 10 035B09012 100 Rev 4 ...
Page 36: ...Page Left Intentionally Blank 09 03 6 6 035B09012 100 Rev 4 ...
Page 40: ...Page Left Intentionally Blank 09 03 7 4 035B09012 100 Rev 4 ...
Page 68: ...Notes 09 03 11 2 035B09012 100 Rev 4 ...
Page 69: ...Notes 09 03 035B09012 100 Rev 4 11 3 ...