background image

©York Survey Supply Centre 2018

Ref:.. \operat98\instructions 18\51248.qxp 05-01-18

MultiScanner i700

Multifunction Wall Scanner

Congratulations  on  purchasing  the  most  technically  advanced  wall 

scanner ever created! Zircon introduced the StudSensor in 1980 and has

put over 25 years of research into developing OneStep, the advanced

technology at the core of the MultiScanner i700. OneStep technology

senses, processes and adapts to wall surfaces to provide high-definition

visibility into walls, floors and ceilings. MultiScanner i700 is the fastest, 

most accurate and easiest-to-use wall scanner on the market today.

1. INSTALLING THE BATTERY

Press battery door release in with your finger or a coin and lift up to 

remove door.

Place  9V  battery  into  the  compartment  and  press  into  place.

Replace battery door and snap shut. Battery will last approximately 2 

years under normal conditions.

2. SELECTING THE MODE

Move selector switch to the desired mode: STUD SCAN for finding wood

or metal studs; METAL SCAN for locating metal; or AC SCAN for locating 

hot AC wiring.

Move selector switch to the OFF position when not in use to prevent the 

tool from accidentally powering on and wearing down the battery.

3. FINDING A STUD

Always start with the scanner placed against the wall, then press the 

handle down. Wait for beep to confirm calibration has completed before 

moving tool.

Slowly slide tool across surface. EDGE

display will illuminate, indicating location 

of the stud edge.

Continue sliding tool. When the centre of

the stud is located with three bars on the

Signal Strength Indicator, the buzzer will

sound and the four middle bars, CENTRE 

display and SpotLite will illuminate.

In cases of deeper studs (or thicker walls)

two bars will show on the Signal Strength

Indicator and only the SpotLite and four

middle bars will illuminate. If you still can’t 

locate a stud, try the next step.

Quickly (within one second) release and

re-press the handle down. The scanner

will enter the 

High Sensitivity Mode

and

the Stud Scan Mode Indication will flash

continuously. The centre of a very deep

stud will be indicated by the four middle 

bars illuminating.

4. TIPS FOR PROPER OPERATION

For optimum scanning results it is important to

properly hold MultiScanner i700 and move slowly

when  scanning.  The  following  tips  will  ensure 

accurate scanning results:

• Grasp the handle with your thumb on one side

and your fingers on the other side. Make sure your

fingertips  are  resting  on  or  above  the  running

board and not touching the surface being scanned 

or the scanning head of the tool.

• Hold the tool straight up and down, parallel to the 

studs and do not rotate the tool.

• Keep tool flat against the wall and do not rock or

tilt the tool when slowly sliding across the surface 

being scanned.

• Make sure your other hand or any other part of

your  body  is  not  touching  the  surface  being

scanned.  This  could  interfere  with  the  tool’s 

performance.

5. CALIBRATING THE TOOL

MultiScanner i700 is the world’s first StudSensor that can be calibrated 

anywhere on the wall.

• Place MultiScanner i700 against the wall and press the handle until it

lays flat against the wall. Pressing the tool to lay flat against the wall will 

automatically power on the tool via the internal on/off switch.

• Once powered on, tool will automatically perform all calibrations. The

LCD will display all icons until calibration is complete. Upon  completion

of calibration, the SpotLites and buzzer will momentarily activate and the

tool will begin continuous measurements. Continue to press the tool flat 

against the wall and begin scanning.

Note: It is important to wait for calibration to complete (1-2 seconds) 

before moving the scanner.

• One of the most important factors in ensuring scanning accuracy is 

calibrating the tool away from a stud, so the tool will sense increased

density  over  the  stud.  During  scanning,  the  tool  will  automatically 

recalibrate itself when needed. This recalibration is usually transparent 

and no indication is made.

If the tool is initially calibrated

near a stud then moved away (it

will detect the density of the wall

decreasing) an arrow icon will

be  illuminated,  indicating  the 

direction of the missed stud.

6. SCANNING IN METAL MODE

Press the tool flat against the wall and slowly slide the scanner across

the surface. MARK the spot where the display bars peak and the steady

tone sounds. The SpotLites will also shine a beam of light. Continue in 

same direction until display bars reduce.

Reverse direction and MARK the spot where the display bars peak from

the reversed direction. The midpoint of the two marks is the location of 

the centre of the metal object.

7. SCANNING IN AC MODE

Press the tool flat against the wall and slowly slide the scanner across

the surface. MARK the spot where the display bars peak and the steady

tone sounds. The SpotLites will also shine a beam of light. Continue in 

same direction until display bars reduce.

Reverse direction and MARK the spot where the display bars peak from

the reversed direction. The midpoint of the two marks is the location of 

the centre of the electrical object.

Note: AC SCAN mode will only detect hot AC wiring.

AC WireWarning

Zircon’s AC WireWarning feature works continuously in all modes. When

AC voltage is detected, the AC Alert warning icon will appear in the 

display.

CAUTION: Wires deeper than 2 inches (51mm) from the surface, in 

conduit, or behind plywood shear wall may not be detected. Use extreme

caution under these circumstances or whenever hot AC wiring is present. 

Always turn off power when working near electrical wires.

8. WORKING WITH DIFFERENT MATERIALS

Wallpaper:

The MultiScanner i700 functions normally on walls covered

with wallpaper or fabric, unless the materials are metallic foil, contain 

metallic fibres or are still wet after application.

Lath and Plaster:

Due to irregularities in plaster thickness, it is difficult

for the MultiScanner i700 to locate studs in STUD SCAN mode. Change

to METAL SCAN mode to locate nail heads holding laths to stud. If plaster

has internal mesh reinforcement, MultiScanner i700 will be unable to 

detect through that material.

Textured walls or acoustic ceilings:

When scanning a ceiling or wall

with  an  uneven  surface,  place  thin  cardboard  on  the  surface  to  be 

scanned and scan over the cardboard. Calibrate with cardboard in place.

Wood  flooring,  subflooring  or  gypsum  drywall  over  plywood 

sheathing:

Use STUD SCAN mode and move the tool slowly. The signal

strength indicator may only display 1 or 2 bars when the tool locates a 

stud through thick surfaces.

MultiScanner  i700  cannot  scan  for  wood  studs  and  joists  through 

carpeting and pad. In problematic situations, try using METAL SCAN to

locate  nails  or  drywall  screws  that  line  up  vertically  where  stud  is 

positioned.

Note: Sensing depth and accuracy can vary due to moisture content of 

materials, wall texture and paint.

9. MARKING THE LOCATION

Once an object is located, you can MARK the location by gently pulling

down the MARK button with the tip of your finger. Pulling back the MARK

button will cause a pencil point to extend from the front of the handle, 

placing a short erasable line on the wall.

10. CHANGING THE MARKER TIP

Pull and hold the MARK button to fully extend the marker tip. Grasp the

marker and pull it off the marker post. To install a new marker tip, pull and

hold the MARK button to fully extend the marker post. Push the new 

marker onto the marker post.

Note: MultiScanner i700 comes with three spare marker tips. These tips 

are stored in a compartment behind the battery.

11. REMOVING OR REPLACING THE SCANNING HEAD

MultiScanner i700’s scanner head may be removed from the handle to

facilitate cleaning or repair. Or the scanning head may also become 

separated from the handle if accidentally dropped or twisted. Follow the 

directions below to replace the scanning head:

To remove head:

Place the back of the head in the palm of one hand

and grasp the body of the unit in the other hand. Slowly and gently lift 

and turn the body, removing one arm from the socket at a time.

To replace the head:

Align the end of the arms over the sockets and 

gently snap them back into their sockets, one arm at a time.

12. HELPFUL HINTS

(See also number 4, Tips for Proper Operation)

Situation

Probable Cause

Solution

Detects other objects 

besides studs in STUD

SCAN mode. Finds more

targets than there should

be.

• Electrical wiring and metal/plastic 

pipes may be near or touching back 

surface of the wall.

• Scan the area in METAL and AC SCAN modes to 

determine if metal or hot AC is present.

• Check for other studs equally spaced to either side (12, 16 

or 24in [305, 406 or 610mm]) apart or the same stud at 

several places directly above or below the first.

Use CAUTION when nailing, sawing or drilling in walls, floors and

ceilings where these items may exist

Area of voltage appears

much larger than actual wire

(AC only)

• Static charge may develop on dry

wall, spreading voltage detection as 

much as 12in (305mm) laterally from 

each side of an actual electrical 

wire.

• To narrow detection, turn unit off and on again at the edge 

of where the wire was first detected and scan again.

• Place your free hand flat against the wall near the tool 

during the entire scan to drain static.

Difficulty detecting metal

• Tool calibrated over metal object.

• Metal targets too deep.

• The scanner may have been calibrated over a metal 

object, reducing sensitivity. Try calibrating in another 

location.

• Scan in both horizontal and vertical directions. Metal 

sensitivity is increased when metal object is parallel to 

sensor, located under Zircon logo.

Image of metal object 

appears wider than 

actual size

• Metal has greater density than wood

• To reduce sensitivity, recalibrate MultiScanner i700 over 

either of the first two marks.

Constant readings of studs

near windows and doors

• Double and triple studs are usually 

found around doors and windows. 

Solid headers are above them.

• Detect outer edges so you know where to begin.

You suspect electrical wires

but do not detect any.

• Wires may be shielded in metal 

conduit or behind metallic wall 

covering.

• Wires deeper than 2in (51mm) from 

surface might not be detected.

• Wires may not be hot.

• Try METAL SCAN to see if you can find metal, wire or 

metal conduit.

• Always turn off the power when working near electrical 

wires.

• Try turning on switches to outlet.

• Try plugging a lamp into  outlet and turning on switch.

Reviews: