background image

TECHNICAL GUIDE

AFFINITY

MODELS: PC9

GAS-FIRED
CONDENSING / HIGH EFFICIENCY
DOWNFLOW / HORIZONTAL 
MODULATING FURNACES
WITH ECM MOTOR

NATURAL GAS
60 - 120 MBH INPUT

Due to continuous product improvement, 
specifications are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

036-21671-001 Rev. A (0106)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.

FEATURES

• Modulating heating operation includes:

- Modulating gas valve
- Modulating inducer operation

• Provides increased comfort level & very quiet unit opera-

tion

• Adjustable delay timer allows two stage operation with sin-

gle stage thermostat.

• Compact, easy to install, ideal height 40" cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• High velocity filter available for easy field installation.
• May be installed as either two-pipe (sealed combustion) or 

single pipe vent (using indoor combustion air)

• Top intake & vent connection allows installation in narrow 

locations.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• ECM High-efficiency, direct drive motor with large, quiet 

blower.

• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-

grade stainless steel.

• Timed on, adjustable off blower capability for maximum 

comfort.

• Independent door removal for greater durabilty and ease 

of access.

• Easy access from front of unit for cleaning, maintenance or 

service.

• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• 3-way transition facilitates fresh air piping.

Summary of Contents for Affinity PC9

Page 1: ...nducer operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with sin gle stage thermostat Compact easy to install ideal height 40 cab...

Page 2: ...ls CFM Cabinet Size Cabinet Dimension A in B in C in D in E IN PC9B12N060DH11 1200 B 17 1 2 16 1 4 15 1 3 4 2 3 8 PC9B12N080DH11 1200 B 17 1 2 16 1 4 15 1 3 4 2 3 8 PC9C16N080DH11 1600 C 21 19 3 4 18...

Page 3: ...0 A C 1370 920 1560 1010 C B 1290 850 1470 940 B C 1130 790 1370 890 D B 1230 850 1460 930 C A 1050 720 1250 790 D A 1110 760 1310 810 C C 950 660 1090 690 D C PC9D20N120DH11 JUMPER SETTINGS CFM High...

Page 4: ...e following example Example For a 120 000 Btuh furnace operating on high speed blower it is found that total system static is 0 58 w c To determine the system airflow complete the following steps 1 Ob...

Page 5: ...Stage Cool Y First Stage Cool Y Y2 Single Second Stage Cool Y Single Stage Cool Y1 First Stage Cool RC 24 Volt Hot Cool XFMR RC 24 Volt Hot Cool XFMR RC 24 Volt Hot Cool XFMR HUM Dehumidification Ope...

Page 6: ...Humidity Rise Y1 First Stage Cool Y2 Second Stage Cool W2 Second Stage Heat Y2 Second Stage Cool Y First Stage Cool E W1 First Stage Heat Y2 Second Stage Cool R 24 Volt Hot R 24 Volt Hot R 24 Volt Ho...

Page 7: ...sidewall Allows combustion air to enter and exhaust to exit through single common hole Elimi nates unslightly elbows for a cleaner installation COMBUSTIBLE FLOOR BASE 1CB0317 17 1 2 Cabinet 1CB0321 2...

Page 8: ...ct to change without notice Printed in U S A 036 21671 001 Rev A 0106 Copyright by York International Corp 2006 All rights reserved Supersedes Nothing Unitary 5005 Norman Products York OK Group Drive...