036-21671-001 Rev. A (0106)
6
Unitary Products Group
THERMOSTAT CHART - TWO STAGE AC
AC20
2 Stage Scroll A/C w/Modulating Furnace, 2 Stage Cooling Ready - P(C/M)8/9
G
Fan
Connection of the "C"
Termainal, 24-Volt
Common, is optional
when used with batteries
Thermostat Installer Setup
Number 1 - System Type -
must be set to 8 -
1 Heat/2 Cool Conventional
Connection of the "C"
Termainal, 24-Volt
Common, is optional
when used with batteries
C
24-Volt Common
THERMOSTAT
*PP32U70124
E2/P Switch must be in
the E2 position and the
Humidistat Jumper on
CFM Control must be in
the 'YES' position for
Dehumidification
THERMOSTAT
*PP32U71124
*PP32U72124
G
Fan
C
24-Volt Common
Y1
First Stage Cool
DHM
Dehumidistat
Step 1 of Thermostat User
Configuration Menu must be set
to MLTI STG
Step 16 of Thermostat User
Configuration Menu must
be set to ON to use
Comfort Alert Features
HM
Humidistat
24V HUMIDIFIER
(Optional)
W
First Stage Heat
E/W1
First Stage Heat
W
Heat (Modulating)
G
Fan
L
Malfunction Light
W2
Second Stage Heat
Comfort Alert
Interface
HUM
Dehumidification - Open on Humidity Rise
Y1
First Stage Cool
Y2
Second Stage Cool
W2
Second Stage Heat
Y2
Second Stage Cool
Y
First Stage Cool
E/W1
First Stage Heat
Y2
Second Stage Cool
R
24-Volt Hot
R
24-Volt Hot
R
24-Volt Hot
Y2
Second Stage Cool
Y/Y2
Single/Second Stage Cool
THERMOSTAT
THERMOSTAT
THERMOSTAT
*DN22C00124
*DP22U70124
*DN22U00124
Y1
First Stage Cool
C
24-Volt Common
C
24-Volt Common
TWO STAGE
AIR CONDITIONING
MODULATING
FURNACE CONTROL
Y1
First Stage Cool
C
24-Volt Common
G
Fan
C
24-Volt Common
Y
First Stage Cool
W2
Second Stage Heat
E/W1
First Stage Heat
RC
24-Volt Hot (Cool XFMR)
C
24-Volt Common
Y2
Second Stage Cool
Step 1 of Thermostat
User Configuration Menu
must be set to MS 2
R
24-Volt Hot
G
Fan
W2
Second Stage Heat
Connection of the "C"
Termainal, 24-Volt
Common, is optional
when used with batteries
G
Fan
Connection of the "C"
Termainal, 24-Volt Common,
is optional
when used with batteries
Thermostat Installer Setup
Number 15 - Compressor
Protection - must be set to 5
R
24-Volt Hot (Heat XFMR)
Y
First Stage Cool
R
24-Volt Hot
Thermostat Installer
Setup Number 0170 -
System Type - must be
set to 8 - 2 Heat/2 Cool
Multistage Conventional
Y2
Second Stage Cool
R
24-Volt Hot (Heat XFMR)
RC
24-Volt Hot (Cool XFMR)
E/W1
First Stage Heat
W2
Second Stage Heat