background image

TECHNICAL GUIDE

AFFINITY 

MODELS: PS8*UH

GAS-FIRED
HIGH EFFICIENCY SINGLE STAGE 
UPFLOW/HORIZONTAL FURNACES

STANDARD & Low NOx 

80% AFUE

NATURAL GAS
40 - 130 MBH INPUT

Due to continuous product improvement, 
specifications are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

278432-YTG-A-0407

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer 
aluminized tubular heat exchangers. The units are factory 
shipped for installation  in upflow or horizontal applications.

These furnaces are designed for residential installation in a 
basement, closet, alcove, attic, recreation room or garage 
and are also ideal for commercial applications. All units are 
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.

These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code.

WARRANTY

20-year limited warranty on the heat exchanger.

10-year heat exchanger warranty on commercial applica-
tions.

5-year limited parts warranty.

FEATURES

• Compact, easy to install, ideal height 40" cabinet.

• Blower-off delay for cooling SEER improvement.

• Easy to connect power/control wiring.

• Built-in, high level self diagnostics with fault code display.

• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• 100% shut off main gas valve for extra safety.

• Multi-speed PSC, large, quiet direct-drive blower motor to 

match cooling requirements.

• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.

• Timed on, adjustable off blower capability for maximum 

comfort.

• Solid removable bottom panel allows easy application.

• Easy access from front of unit for cleaning, maintenance 

or service.

• Insulated blower compartment for quiet operation.

• Independent door removal for greater durability and ease 

of access.

• Low NOx models have been designed to meet specific 

code requirements.

• All models are propane convertible.

Summary of Contents for AFFINITY PS8*UH

Page 1: ...appliance as allowed by the National Fuel Gas Code WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger warranty on commercial applica tions 5 year limited parts warranty FEA...

Page 2: ...12 N L 040UH11 1200 A 14 1 2 13 1 4 11 1 2 10 1 8 PS8A12 N L 060UH11 1200 A 14 1 2 13 1 4 11 1 2 10 1 8 PS8A12 N L 080UH11 1200 A 14 1 2 13 1 4 11 1 2 10 1 8 PS8B16 N L 080UH11 1600 B 17 1 2 16 1 4 14...

Page 3: ...N L 100UH11 100 80 1200 17 1 2 12 0 80 0 40 70 PS8B16 N L 100UH11 100 80 1600 17 1 2 12 0 80 0 35 65 PS8C20 N L 100UH11 100 80 2000 21 14 0 80 0 25 55 PS8C16N115UH11 115 92 1600 21 12 0 80 0 35 65 PS...

Page 4: ...970 1840 1730 1680 1570 1460 1260 Medium Low 1720 1700 1670 1620 1570 1500 1430 1310 1160 1000 Low 1410 1390 1360 1330 1280 1220 1170 1060 930 840 PS8B12 N L 100UH11 High 1700 1620 1560 1480 1390 1300...

Page 5: ...High 2710 2640 2560 2480 2360 2260 2160 2010 1860 1650 Medium High 2110 2110 2070 2030 1980 1910 1850 1710 1570 1300 Medium Low 1690 1690 1650 1610 1540 1480 1410 1280 1170 1030 Low 1350 1330 1310 129...

Page 6: ...ters may not exceed 300 feet per minute All velocities over this require the use of high velocity filters 2 Air flows above 1800 CFM require either return from two sides or one side plus bottom RECOMM...

Page 7: ...Cool Y Single Stage Cool DN11C00124 C 24 Volt Common C 24 Volt Common Optional w Batteries BN11C01124 DP11C40124 PSC 2 STAGE COOLING READY FURNACE CONTROL SINGLE STAGE AIR CONDITIONING BN11C00124 BP11...

Page 8: ...CFM 33 4 m3 min Subtract the airflow 0 50 w c 125 Pa from the airflow 0 60 w c 150 Pa to obtain airflow difference 1180 1250 70 CFM 12 m3 min Subtract the total system static from 0 50 w c 125 Pa and...