036-21610-001 Rev. A (0804)

4

Unitary Products Group

Indicates models available in LoNOx.

NOTES:

1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m

3

/min).

2. Return air is through side opposite motor (left side).
3. Airflows above 1800 CFM (50.97 m

3

/min) require either return from two sides or one side plus bottom.

4. Motor voltage at 115 V.
5. NR = Operation at this static pressure is not recommended.

FILTER PERFORMANCE

The airflow capacity data published in the “Blower Perfor-
mance” table listed above represents blower performance
WITHOUT filters. To determine the approximate blower per-
formance of the system, apply the filter drop value for the fil-
ter being used or select an appropriate value from the “Filter
Performance” table shown below.

NOTE: 

The filter pressure drop values in the “Filter Perfor-

mance” table shown below are typical values for the type of 
filter listed and should only be used as a guideline. Actual 
pressure drop ratings for each filter type vary between filter 
manufacturer.

BLOWER PERFORMANCE CFM - (WITHOUT FILTER)

MODELS 

Input/Output/

Airflow/cabinet

Speed 

Tap 

EXTERNAL STATIC PRESSURE, INCHES WC  

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

cfm

cfm

cfm

cfm

cfm

cfm

cfm

cfm

cfm

cfm

40/32/1200/"A" †

 60/48/1200/"A" †
 80/64/1200/"A" †

HIGH  1580 1530 1470 1405 1330 1245 1150 1045  890  650 

MED-HIGH

1110 1100 

1075 

1060 

1030 980 920 835 680 520 

MED-LOW

845 840 830 815 790 750 670 595 480 320 

LOW  675 665 660 645 620 585 530 455 360 255 

80/64/1600/"B" †

HIGH  1970 1935 1900 1850 1795 1735 1660 1590 1495 1395 

MED  1445 1435 1425 1415 1405 1375 1350 1300 1240 1160 

LOW  1245 1235 1225 1215 1205 1190 1170 1135 1090  995 

100/80/1200/"B" †

HIGH  1675 1645 1595 1530 1465 1385 1280 1155 1025  810 

MED  1270 1260 1250 1240 1215 1185 1125 1035  910  695 

LOW  955 950 945 935 920 905 865 810 685 510 

115/92/1600/"C"

HIGH  2040 1975 1925 1855 1780 1695 1610 1505 1380 1225 

MED  1725 1685 1650 1610 1555 1500 1425 1340 1220 1075 

LOW  1365 1355 1325 1290 1265 1250 1210 1140 1045  940 

 100/80/2000/"C" †
 115/92/2000/"C" †

HIGH  2400 2320 2275 2200 2115 2025 1930 1825 1700 1570 

MED  2050 2025 1980 1930 1855 1805 1720 1635 1530 1400 

LOW  1690 1675 1660 1630 1610 1560 1500 1430 1330 1225 

130/104/2000/"D" †

HIGH  2380 2330 2270 2205 2120 2025 1920 1815 1705 1565 

MED  2040 2010 1980 1920 1875 1790 1705 1610 1515 1385 

LOW  1690 1680 1655 1630 1590 1530 1490 1425 1350 1235 

NOTE: Data below reflects airflows with two return openings - two sides or one side and bottom 

80/64/2000/"C" 

100/80/2000/"C" †

115/92/2000/“C" † 

HIGH  2405 2340 2275 2210 2130 2050 1955 1840 1725 1600 

MED  2005 1990 1965 1935 1880 1815 1725 1635 1535 1410 

LOW  1655 1640 1625 1610 1585 1540 1485 1420 1340 1235 

130/104/2000/"D" † 

HIGH  2385 2335 2275 2195 2120 2040 1935 1820 1700 1555 

MED  2005 1980 1955 1905 1845 1775 1700 1610 1500 1370 

LOW  1640 1635 1620 1605 1575 1540 1480 1400 1330 1225 

BLK

WHT

GRN

BLK (HOT)

WHT (NEUTRAL)

GRN

NOMINAL
120 VOLT

Summary of Contents for AFFINITY PS8

Page 1: ...tegory I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger warranty on...

Page 2: ...3 4 100 80 1200 B 17 1 2 16 1 4 13 1 8 4 0 11 5 8 3 3 4 100 80 2000 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4 115 92 1600 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4 115 92 2000 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4...

Page 3: ...0 14 1 2 80 0 35 65 80 64 1600 17 1 2 80 0 25 55 100 80 1200 17 1 2 80 0 40 70 100 80 2000 21 80 0 25 55 115 92 1600 21 80 0 35 65 115 92 2000 21 80 0 30 60 130 104 2000 24 1 2 80 0 40 70 Input MBH Ma...

Page 4: ...1060 1030 980 920 835 680 520 MED LOW 845 840 830 815 790 750 670 595 480 320 LOW 675 665 660 645 620 585 530 455 360 255 80 64 1600 B HIGH 1970 1935 1900 1850 1795 1735 1660 1590 1495 1395 MED 1445...

Page 5: ...tem static is 0 58 w c To determine the system airflow com plete the following steps 1 Obtain the airflow values at 0 50 0 60 ESP Airflow 0 50 2120 CFM Airflow 0 60 2040 CFM 2 Subtract the airflow 0...

Page 6: ...100 80 1PS0312 1PS0311 115 92 1PS0312 1PS0311 130 104 1PS0312 1PS0311 FIELD INSTALLED ACCESSORIES ELECTRICAL MODEL NO DESCRIPTION USED WITH 2TB17700424 SUBBASE 24V One stage Heat Cool Manual changeov...

Page 7: ...036 21610 001 Rev A 0804 Unitary Products Group 7 NOTES...

Page 8: ...to change without notice Printed in U S A 036 21610 001 Rev A 0804 Copyright by York International Corp 2004 All rights reserved Supersedes Nothing Unitary 5005 Norman Products York OK Group Drive 730...

Reviews: