036-21610-002 Rev. A (1104)
Unitary Products Group
3
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
1. All filters must be high velocity cleanable type.
RATINGS & PHYSICAL / ELECTRICAL DATA
Models
Input
MBH
Output
MBH
Nominal CFM
AFUE
Air Temp.
Rise °F
PS8A12N040DN11
40
32 1200 80.0
20-50
PS8A12N060DN11
57
48 1200 80.0
25-55
PS8A12N080DN11
80
64 1200 80.0
35-65
PS8B16N080DN11
80
64 1600
80.0
25-55
PS8B12N100DN11
100
80 1200 80.0
40-70
PS8C20N100DN11
100
80 2000
80.0
25-55
PS8C16N115DN11
115
92 1600 80.0
35-65
PS8C20N115DN11
115
92 2000 80.0
30-60
PS8D20N130DN11
130
104 2000 80.0
40-70
Models
Max. Outlet
Air Temp °F
Blower
Blower
Size In.
Total Unit
Amps
Max
Over-current
protect
Min.
Wire Size (awg)
@ 75 ft. one way
Operation
WGT. LBS
Hp
Amps
PS8A12N040DN11
150
1/3
6.2
10 x 8
9.0
15
14
100
PS8A12N060DN11
155
1/3
6.2
10 x 8
9.0
15
14
110
PS8A12N080DN11
165
1/3
6.2
10 x 8
9.0
15
14
120
PS8B16N080DN11
160
3/4
11.0
11 x10
12.0
15
14
130
PS8B12N100DN11
170
1/2
7.0
10 x 8
12.0
15
14
125
PS8C20N100DN11
155
1
12.2
11 x 10
14.0
20
12
140
PS8C16N115DN11
165
3/4
11.0
11 x 10
12.0
15
14
150
PS8C20N115DN11
160
1
12.2
11 x 10
14.0
20
12
150
PS8D20N130DN11
170
1
12.2
11 x 10
14.0
20
12
160
FILTER SIZES
Models
Cabinet Size
Top Return Filter (in)
PS8A12N040DN11
A
(2) 14 x 20
PS8A12N060DN11
A
(2) 14 x 20
PS8A12N080DN11
A
(2) 14 x 20
PS8B16N080DN11
B
(2) 14 x 20
PS8B12N100DN11
B
(2) 14 x 20
PS8C20N100DN11
C
(2) 14 x 20
PS8C16N115DN11
C
(2) 14 x 20
PS8C20N115DN11
C
(2) 14 x 20
PS8D20N130DN11
D
(2) 14 x 20