AYK550-UH User’s Manual
66
Start-Up
-12 =
DI
1,2,3(
INV
) – Selects one of seven Constant Speeds (1…
7
) using
DI
1,
DI
2 and
DI
3.
• Inverse operation uses three digital inputs, as defined below (0 =
DI
de-activated, 1 =
DI
activated):
-13 =
DI
3,4,5(
INV
) – Selects one of seven Constant Speeds (1…3) using
DI
3,
DI
4 and
DI
5.
• See above (
DI
1,2,3(
INV
)) for code.
-14 =
DI
4,5,6(
INV
) – Selects one of seven Constant Speeds (1…3) using
DI
4,
DI
5 and
DI
6.
• See above (
DI
1,2,3(
INV
)) for code.
1202
CONST SPEED 1
0…30000 rpm /
1 rpm /
360 (US)/
0.0…500.0 Hz
0.1 Hz
6.0 (US)
Sets value for Constant Speed 1.
• The range and units depend on parameter 9904
MOTOR
CTRL
MODE
.
• Range: 0…30000 rpm when 9904 = 1 (
VECTOR
:
SPEED
).
• Range: 0…500 Hz when 9904 = 3 (
SCALAR
:
FREQ
).
1203
CONST SPEED 2
0…30000 rpm /
1 rpm /
360 (US)/
0.0…500.0 Hz
0.1 Hz
12.0 (US)
Sets a value for a Constant Speed. (See
CONST
SPEED
1 above.)
1204
CONST SPEED 3
0…30000 rpm /
1 rpm /
720
(US)/
0.0…500.0 Hz
0.1 Hz
18.0 (US)
1205
CONST SPEED 3
0…30000 rpm /
1 rpm /
1080 (US)/
0.0…500.0 Hz
0.1 Hz
18.0 (US)
Sets a value for a Constant Speed. (See
CONST
SPEED
1 above.)
1206
CONST SPEED 3
0…30000 rpm /
1 rpm /
1440 (US)/
0.0…500.0 Hz
0.1 Hz
24.0 (US)
Sets a value for a Constant Speed. (See
CONST
SPEED
1 above.)
1207
CONST SPEED 3
0…30000 rpm /
1 rpm /
1800 (US)/
0.0…500.0 Hz
0.1 Hz
30.0 (US)
Sets a value for a Constant Speed. (See
CONST
SPEED
1 above.)
1208
CONST SPEED 3
0…30000 rpm /
1 rpm /
2880 (US)/
0.0…500.0 Hz
0.1 Hz
48.0 (US)
Sets a value for a Constant Speed. (See
CONST
SPEED
1 above.)
1209
TIMED MODE SEL
1…2
1
2
9
Uses the timer(s) specified by parameter 1201, values 15…19, to override the reference defined in Group 11,
Reference Select. This override applies only if the timer function is enabled (parameter 3601).
1 =
EXT
/
CS
1/2/3 – The state of the timer(s) specified by param 1201, values 15…19, determines the reference
used. See tables in 1201 at appropriate value.
2 =
CS
1/2/3/4 – The state of the timer(s) specified by param 1201, values 15…19, determines the reference used.
See tables in 1201 at appropriate value.
Group 12: Constant Speeds
Code
Description Range
Resolution
Default
S
DI
1
DI
2
DI
3
Function
1
1
1 No constant speed
0
1
1 Constant speed 1 (1202)
1
0
1 Constant speed 2 (1203)
0
0
1 Constant speed 3 (1204)
1
1
0 Constant speed 4 (1205)
0
1
0 Constant speed 5 (1206)
1
0
0 Constant speed 6 (1207)
0
0
0 Constant speed 7 (1208)