567175-YTG-E-0512
2
Johnson Controls Unitary Products
All dimensions are in inches. They are subject to change with-
out notice. Certified dimensions will be provided upon request.
*
Expander fitting required for 1-1/8” line set.
PHYSICAL AND ELECTRICAL DATA
MODEL
CZF02413(C)
CZF03013(C)
CZF03613(C)
CZF04213(C)
CZF04813(C)
CZF06013(C)
Unit Supply Voltage
208-230V, 1
60Hz
Normal Voltage Range
1
187 to 252
Minimum Circuit Ampacity
17.3
18.1
22.9
23.7
27.7
29.5
Max. Overcurrent Device Amps
2
30
30
40
40
45
50
Min. Overcurrent Device Amps
3
20
20
25
25
30
35
Multi-Stage
Compressor
No No No No No No
Compressor
Type
Scroll Scroll Scroll Scroll Scroll Scroll
Compressor Amps
Rated Load
13.4
14.1
17.3
17.9
21.1
21.4
Locked Rotor
58.3
73.0
96.7
112
106
135
Crankcase
Heater
No No No No No No
Factory External Discharge Muffler
No
No
No
No
No
No
Factory External Check Valve
No
No
No
No
No
No
HS Kit Required with TXV
4
No
No
No
No
No
No
Fan Motor Amps
Rated Load
0.5
0.5
1.3
1.3
1.3
2.8
Fan Diameter Inches
22
22
22
22
24
24
Fan Motor
Rated HP
1/15
1/15
1/4
1/4
1/4
1/3
Nominal RPM
850
850
850
850
850
917
Nominal CFM
2020
2045
3240
3300
3800
3900
Coil
Face Area Sq. Ft.
14.10
13.97
16.12
19.34
22.82
22.82
Rows Deep
1
1
1
1
1
1
Fins / Inch
23
23
23
23
23
23
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
3/4
3/4
3/4
7/8
7/8
1-1/8
Unit Charge (Lbs. - Oz.)
5
3 - 12
4 - 6
5 - 0
6 - 4
6 - 5
6 -14
Charge Per Foot, Oz.
0.62
0.62
0.62
0.67
0.67
0.75
Operating Weight Lbs.
159
166
192
209
225
235
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,
add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
VAPOR
LIQUID
2-3/8
3-1/8 6-1/2
C
A
B
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
B
C
Liquid
Vapor
024
29-1/2
37
31
3/8”
3/4”
030
29-1/2
37
31
036
33-1/2
37
31
042
39-1/2
37
31
7/8”
048
39-1/2
42
34
060
39-1/2
42
34
7/8” *