233
Installation
Installation
1.
2. Select a position where the condensing water can be easily drained out, and the place is easily
connected for outdoor unit
.
4. Can select the place where is strong enough to withstand the full weight and vibration of the unit.
And will not increase the noise
.
5.
6.7.
8
.
Make sure that the indoor unit installation should accord with installation dimension diagram
requirements.
1. Select a location from which noise and outflow air emitted by unit will not inconvenience neighbors,
animals, plants.
2. Select a location where there should be sufficient ventilation.
3. Select a location where there should be no obstructions cover the inlet and outlet vent.
4. The location should be able to withstand the full weight and vibration of the outdoor unit and permit
safe installation.
5. Select a dry place, but do not expose under the direct sunlight or strong wind.
6.
3. Select a location where the children can not reach.
1. The unit installation work must be done by qualified personnel according to the local rules and this
manual
.
2. Before installating, please contact with local authorized maintenance center, if unit is not installed
by the authorized maintenance center, the malfunction may not solved
,
due to discommodious contacts
.
.
3. When removing the unit to the other place, please firstly contact with the authorized Maintenance
Center in the local area.
●
●
7.
8.9.
●
●
●
●
Important Notices
Basic Requirements For Installation Position
Install in the following place may cause malfunction. If it is unavoidable contact with service center please:
Place where strong heat sources, vapors, flammable gas or volatile object are emitted.
Place where high-frequency waves are generated by radio equipment, welders and medical equipment.
Place where a lot of salinities such as coast exists.
Place where the oil (machine oil) is contained in the air.
Place where a sulfured gas such as the hot spring zones is generated.
Other place with special circumstance.
Indoor Unit Installation Position Selection
The air inlet and outlet vent should be far from the obstruction, make sure that the air can be blown
through the whole room.
Be sure to leave enough space to allow access for routine maintenance. The height of the installed
location should be 250cm or more from the floor.
Select a place about 1m or more away from TVset or any other electric appliances.
Select a place where the filter can be easily taken out.
Outdoor Unit Installation Position Selection
Make sure that the outdoor unit installation dimension should accord with installation dimension
diagram, convenient for maintenance, repair.
The height difference of connecting the tubing within 5m, the length of connecting the tubing within 10m.
Select a place where it is out of reach for the children.
Select a place where will not block the passage and do not influence the city appearance.
.
Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.
9
Summary of Contents for EVJC 12
Page 2: ...74 74...
Page 30: ...102...
Page 32: ...104 www johnsoncontrols com...
Page 34: ...106 by johnson controls 2...
Page 46: ...118...
Page 48: ...120 www johnsoncontrols com...
Page 49: ...121 High Wall EVHC 09 to 12 DSAAAR SERVICE MANUAL SM EVHC D 09 12GB 05 10 EVHC 09 EVHC 12...
Page 65: ...137 LULQJ LDJUDP Schematic Diagram Indoor Unit Schematic Diagram...
Page 66: ...138 Schematic Diagram Outdoor Unit...
Page 69: ...141 TOP VIEW Schematic Diagram BOTTOM VIEW 1 3 4 5 6 2 7 8 9 10 11 12 Outdoor Unit...
Page 113: ...185 Exploded View Exploded View Indoor Unit...
Page 114: ...186 Exploded View Outdoor Unit...
Page 118: ...190 High Wall EVHC 18 to 24 DSAAAR SERVICE MANUAL SM EVHC D 18 24GB 05 10 EVHC 18 EVHC 24...
Page 132: ...204 LPHQVLRQV Dimensions QGRRU 8QLW Tube exit Air inlet Right Left Ceiling W D H 02 18K 24K...
Page 133: ...205 890 340 955 560 380 424 700 60cm 60cm 60cm 60cm LPHQVLRQV Outdoor Unit Bolt Nut Spanner...
Page 140: ...212 TOP VIEW Schematic Diagram BOTTOM VIEW 1 2 3 4 5 6 7 8 9 7 8 9 10 11 12 13 1 2 3 4 5 6 10...
Page 142: ...214 Schematic Diagram Key testing spot bottom...
Page 197: ...269 Exploded View Exploded View Indoor Unit 78 Model EVKC 18 DS...
Page 198: ...270 Exploded View Model EVKC 24 DS 79...
Page 199: ...271 Exploded View Outdoor Unit 80...