036-21120-002 Rev. A (1102)

6

Unitary Products Group

UNIT CLEARANCES TO COMBUSTIBLES

NOTE:1.

Special floor base or air conditioning coil required for use on combustible floor.

NOTE:2.

Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and 
building joists, studs or framing.

*

Cabinet clearance is "0", vent clearance is required.

ACCESSORIES

Propane Conversion Kit (Standard) – 1NP0366

This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation at altitudes 0-2,000 ft.
Conversion must be made by qualified distributor or dealer
personnel.

Propane Conversion Kit (High Altitude) – 1NP0367

This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation at altitudes from 2,000 to
8,000 ft. Conversion must be made by qualified distributor or
dealer personnel.

Combustible Floor Base

This accessory is used for downflow applications on combus-
tible surfaces.
17-1/2"  "B" Cabinets 1FB0318
21" 

"C" Cabinets 1FB0319

24-1/2"  "D" Cabinets 1FB0320

Bottom External Filter Rack

This accessory is used to upflow/bottom return air applica-
tions. Packaged and sold in quantities of six (6).
17-1/2" "B" Cabinets 1BR0312BK
21"

"C" Cabinets 1BR0316BK

24-1/2"  "D" Cabinets 1BR0320BK

Application

Top

Front

Rear Left Side

Right

Side

Flue

Floor /

Bottom

Closet

Alcove

Attic

Line

Contact

UPFLOW

1

6

0

0

0

6

COMBUSTIBLE

YES

YES

YES

NO

UPFLOW

B-VENT

1

2

0

0

0

1

COMBUSTIBLE

YES

YES

YES

NO

HORIZONTAL

0

6

0

0

1

6

COMBUSTIBLE

NO

YES

YES

YES(See Note

2

)

HORIZONTAL

B-VENT

1

2

0

0

1

1

COMBUSTIBLE

NO

YES

YES

YES(See Note

2

)

DOWNFLOW

1

6

0

0

5*

6

1" (See Note

1

)

YES

YES

YES

NO

DOWNFLOW

B-VENT

1

2

0

0

0

1

1" (See Note

)

YES

YES

YES

NO

Summary of Contents for G8C05012MUB12

Page 1: ...arranty on the heat exchanger 5 year limited parts warranty FEATURES 4 position MU upflow models allow horizontal left hori zontal right downflow and convertible applications 4 position MD models allo...

Page 2: ...0 20 3 8 20 19 1 2 18 1 4 18 3 4 18 5 8 19 42 G8C10020 MU MD D111 24 1 2 23 1 2 20 3 8 20 23 21 3 4 18 3 4 22 1 8 19 42 G8C12520 MU MD D111 24 1 2 23 1 2 20 3 8 20 23 21 3 4 18 3 4 22 1 8 19 52 G8C150...

Page 3: ...or rated at 115 volts No air filters MODEL SPEED TAP EXTERNAL STATIC PRESSURE INCHES W C 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 G8C05012 MU MD B12 HIGH 1507 1433 1371 1300 1223 1132 1040 938 MEDIUM 1239 1215...

Page 4: ...22 1132 1016 G8C12520 MU MD D11 HIGH 2347 2248 2160 2041 1926 1798 1646 1494 MED HI 1740 1700 1666 1596 1524 1447 1349 1216 MED LO 1596 1578 1561 1503 1442 1353 1257 1117 LOW 1460 1431 1398 1372 1323...

Page 5: ...llowing example Example For a 100 000 BTUH furnace with 2 return open ings and operating on high speed blower it is found that total system static is 0 58 w c To determine the system airflow complete...

Page 6: ...tural gas units for propane LP operation at altitudes from 2 000 to 8 000 ft Conversion must be made by qualified distributor or dealer personnel Combustible Floor Base This accessory is used for down...

Page 7: ...036 21120 002 Rev A 1102 Unitary Products Group 7 NOTES...

Page 8: ...nge without notice Printed in U S A 036 21120 002 Rev A 1102 Copyright by York International Corp 2002 All rights reserved Supersedes 036 21120 001 Rev A 0201 Unitary 5005 Norman Products York OK Grou...

Reviews: