background image

279747-YTG-A-0407

Unitary Products Group

7

For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at
www.upgnet.com in the Product Catalog Section.

Thermostat Chart

AC2

THERMOSTAT

THERMOSTAT

THERMOSTAT

1 Stage A/C w/Single Stage Furnace, 2 Stage Cooling Ready - PS8/9, (F,L)*8/9S, XYG80-U

PSC-2 STAGE COOLING READY

FURNACE CONTROL

SINGLE STAGE

AIR CONDITIONING

*BN11C00124

*BP11C50124

*PP11C70224

*BN11C01124

*DP11C40124

*DN11C00124

C

24-Volt Common

C

24-Volt Common

Optional w/Batteries

C

24-Volt Common

C

24-Volt Common

Y

First Stage Cool

Y

First Stage Cool

Y

First Stage Cool

Y/Y2

Single/Second Stage Cool

Y

Single Stage Cool

RC

24-Volt Hot (Cool XFMR)

RC

24-Volt Hot (Cool XFMR)

RC

24-Volt Hot (Cool XFMR)

Y1

First Stage Cool

R

24-Volt Hot (Heat XFMR)

RH

24-Volt Hot (Heat XFMR)

RH

24-Volt Hot (Heat XFMR)

R

24-Volt Hot

24V HUMIDIFIER

G

Fan

G

Fan

G

Fan

G

Fan

W

First Stage Heat

W

First Stage Heat

W

First Stage Heat

W

Single Stage Heat

HM1

Humidistat

Thermostat Installer Setup Number 1 - 

System Type - must be set to 0

Selection of GAS/ELEC switch 

on thermostat not necessary

Thermostat Installer Setup Number 15 - 

Compressor Protection - must be set to 5

HP2

Single Stage H/P - E*RD, E*BD, ERHS, HPX13 - w/Single Stage Furnace, 2 Stage Cooling Ready - PS8/9, (F,L)*8/9S, XYG80-U

W/031-01975- Series Demand Control

Step 1 of Thermostat User Configuration Menu 

must be set to Heat Pump 1

Step 9 of Thermostat User Configuration Menu 

must be set to Pump OFF

*PP32H70124

O

Reversing Valve–Energized in Cool

L

Malfunction Light

X/L

Malfunction Light

W1/66

First Stage Heat Out

G

Fan

G

Fan

W

First Stage Heat

R

24-Volt Hot

W1

Second Stage Heat

Y1

First Stage Cool

C

24-Volt Common

Y

First Stage Heat/Cool

Y/Y2

Single/Second Stage Cool

Y

Single Stage Heat/Cool

N/A

N/A

C

24-Volt Common

C

24-Volt Common

R

24-Volt Hot

R

24-Volt Hot

E

Emergency Heat

W

Single Stage Heat

O

Reversing Valve–Energized in Cool

*DP21H40124

*DN21H00124

*BN21H00124

THERMOSTAT

THERMOSTAT

THERMOSTAT

SINGLE STAGE

HEAT PUMP

*DN22U00124

*BP21H50124

PSC-2 STAGE COOLING 

READY

FURNACE CONTROL

Summary of Contents for GY8S-DH

Page 1: ...and may be common vented with another gas appliance as allowed by the National Fuel Gas Code ANSI Z223 1 latest edition WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger w...

Page 2: ...net Dimension A B C D G L Y8S040A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S060A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S080A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S080B16DH11 1600 B 17 1 2...

Page 3: ...1 2 12 0 80 0 40 70 G L Y8S100C16DH11 100 80 1600 21 12 0 80 0 25 55 G L Y8S100C20DH11 100 80 2000 21 14 0 80 0 25 55 G L Y8S115C16DH11 115 92 1600 21 12 0 80 0 35 65 G L Y8S115C20DH11 115 92 2000 21...

Page 4: ...1491 1412 1311 1192 1049 908 750 Low 1561 1493 1430 1373 1304 1199 1089 967 816 699 G L Y8S100B12DH11 High 1710 1650 1580 1510 1420 1330 1260 1160 1090 930 Medium High 1480 1440 1380 1330 1270 1180 10...

Page 5: ...em Static Pressure ESP without the filter 4 Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to deter...

Page 6: ...ion of compatible thermosets are available to provide optimum performance and features for any installation 1H 1C manual change over electronic non programmable thermostat 1H 1C auto manual changeover...

Page 7: ...eat W First Stage Heat W Single Stage Heat HM1 Humidistat Thermostat Installer Setup Number 1 System Type must be set to 0 Selection of GAS ELEC switch on thermostat not necessary Thermostat Installer...

Page 8: ...change without notice Printed in U S A 279747 YTG A 0407 Copyright by York International Corp 2007 All rights reserved Supersedes 246794 YTG C 0706 Unitary 5005 Norman Products York OK Group Drive 73...

Reviews: