Unitary Products Group

Physical and Electrical Data

Model

H1RA018S78

H1RA024S78

H1RA030S78

H1RA036S78

Unit Supply Voltage

220 - 240V, 1

φ,

 50Hz

Normal Voltage Range 

1

1.Rated in accordance with ARI Standard 110, utilization range “A”.

207 to 253

Minimum Circuit Ampacity

9.8

14.6

20.4

20.8

Max. Overcurrent Device Amps 

2

2.Dual element fuses or HACR circuit breaker.

15

25

35

35

Compressor Type 

Recip

Recip

Recip

Recip

Compressor Amps

Rated Load

7.4

11.3

15.2

15.5

Locked  Rotor

53

65

90

82

Crankcase Heater

No

No

No

No

Fan Motor Amps

Rated Load

.5

.5

1.8

1.8

Fan Diameter Inches

18

18

18

18

Fan Motor

Rated HP

1/12

1/12

1/4

1/4

Nominal RPM

970

970

900

900

Nominal CFM

1,650

1,650

2,350

2,350

Coil

Face  Area  Sq.  Ft.

8.00

8.00

9.15

9.15

Rows Deep

1

1

1

1

Fin / Inches

14

14

16

16

Liquid Line Set OD (Field Installed)

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

3/4

3/4

3/4

3/4

Unit Charge (Lbs. - Oz.) 

3

3.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

3 - 13

3 - 14

3 - 12

4 - 11

Charge Per Foot, Oz.

0.66

0.66

0.68

0.68

Operating Weight Lbs.

118

123

135

137

All dimensions are in inches. They are subject to
change without notice. Certified dimensions will be pro-
vided upon request.

Unit

Model

Dimensions

(Inches)

Refrigerant 

Connection 

Service Valve 

Size

A

1

B

C

Liquid

Vapor

018S78

17

35

23

3/8”

3/4”

024S78

17

35

23

030S78

19

35

23

036S78

19

35

23

1.Including Fan Guard

Summary of Contents for H1RA018S78

Page 1: ...s made of pre painted steel The pre treated flat galvanized steel provides a better paint to steel bond which resists corrosion and rust creep Special primer formulas and matted textured finish insure less fading when exposed to sunlight LOWER INSTALLED COST Installation time and costs are reduced by easy power and control wiring connections Discharge line heat exchanger knockouts are provided if ...

Page 2: ... 650 1 650 2 350 2 350 Coil Face Area Sq Ft 8 00 8 00 9 15 9 15 Rows Deep 1 1 1 1 Fin Inches 14 14 16 16 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 4 3 4 3 4 3 4 Unit Charge Lbs Oz 3 3 The Unit Charge is correct for the outdoor unit matched indoor coil and 15 feet of refrigerant tubing For tubing lengths other than 15 feet add or subtract the amount of r...

Page 3: ... F entering air temperature 50 RH and rated air flow KW includes compressor outdoor fan and indoor blower motor watts Add on coils include 365 watts 1000 CFM for blower motor COOLING PERFORMANCE MODEL SUCT T P COMPR AIR TEMP ON CONDENSER 75 F 95 F 115 F 125 F TEMP PSIG MBH KW MBH KW MBH KW MBH KW H1RA018S78 35 61 5 13 1 1 36 13 1 1 36 10 6 1 46 9 3 1 52 40 68 5 14 8 1 42 14 8 1 42 12 8 1 55 10 6 1...

Page 4: ...CATION 018S78 036S78 UNIT MODEL dBA 018 76 024 78 030 82 036 82 MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE 60 OVERHEAD CLEARANCE 10 CLEARANCE COIL AREA WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL SEAL OPENING S WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL NOTE ALL OUTDOOR WIRING MUST BE WEATHERPROO...

Page 5: ... K W 1 55 1 55 1 53 1 71 1 71 1 69 1 68 1 67 1 66 85 T C 17 8 17 2 15 4 18 0 17 5 16 1 18 2 17 8 16 8 S C 10 6 10 7 10 2 11 3 11 7 11 6 12 0 12 8 13 1 K W 1 76 1 74 0 95 1 95 1 93 1 90 1 95 1 93 1 90 95 T C 17 3 16 3 14 2 17 6 16 8 15 0 17 9 17 3 15 8 S C 10 6 10 5 9 8 11 6 11 8 11 4 12 5 13 1 12 9 K W 1 79 1 75 1 71 1 95 1 92 1 88 1 92 1 89 1 85 105 T C 16 0 14 7 12 6 16 5 15 3 13 3 17 0 15 9 14 ...

Page 6: ...2 15 2 11 2 08 2 17 2 13 2 10 2 18 2 15 2 12 85 T C 25 4 23 9 21 8 25 7 24 6 22 8 26 1 25 2 23 7 S C 15 3 15 1 14 4 16 4 16 6 16 2 17 4 18 2 18 1 K W 2 31 2 26 1 16 2 33 2 28 2 23 2 36 2 31 2 26 95 T C 24 4 22 5 19 6 24 9 23 4 20 9 25 4 24 3 22 2 S C 15 3 14 6 13 4 16 6 16 6 15 7 17 9 18 5 17 9 K W 2 47 2 40 2 31 2 50 2 44 2 35 2 53 2 47 2 39 105 T C 22 5 20 1 17 6 23 2 21 1 18 6 23 9 22 1 19 6 S ...

Page 7: ...2 39 2 35 2 32 2 53 2 49 2 46 2 56 2 53 2 50 85 T C 25 4 23 9 21 8 25 7 24 6 22 8 26 1 25 2 23 7 S C 15 3 15 1 14 4 16 4 16 6 16 2 17 4 18 2 18 1 K W 2 67 2 62 1 40 2 82 2 76 2 71 2 93 2 88 2 83 95 T C 24 4 22 5 19 6 24 9 23 4 20 9 25 4 24 3 22 2 S C 15 3 14 6 13 4 16 6 16 6 15 7 17 9 18 5 17 9 K W 2 71 2 64 2 55 2 86 2 80 2 71 2 91 2 85 2 77 105 T C 22 5 20 1 17 6 23 2 21 1 18 6 23 9 22 1 19 6 S ...

Page 8: ...0 39 1 34 7 35 6 39 4 32 5 36 2 S C 23 4 23 5 23 4 24 4 24 8 24 8 25 4 26 1 26 2 K W 3 30 3 25 3 21 3 59 3 54 3 50 3 48 3 43 3 39 85 T C 37 4 34 8 31 9 37 7 34 1 32 6 38 1 33 4 33 4 S C 23 5 24 0 22 2 24 7 25 2 23 9 25 9 26 4 25 5 K W 3 74 3 65 1 95 4 06 4 00 3 90 4 00 3 94 3 84 95 T C 36 0 32 7 28 7 36 4 33 5 29 6 36 7 34 3 30 5 S C 23 6 24 5 21 0 25 0 25 6 22 9 26 4 26 7 24 8 K W 3 80 3 67 3 51 ...

Reviews: