c) Now we put the front additional jaw on forehead (2) with guiding rods (5) and everything we insert to
base (1) , which is already installed on underneath od working desk . We secure by safety ring (7) and
we fast the jaw of vise on total touch-down . Than we have to seat the top edge of front jaw with top
edge of the rear additional jaws or with edge of collar desk . In case , that everything is O.K. , we can
fast screws
S
2
on base (1)and we fast the forehead (2) to front additional jaw by screws
S
3
after picture
(7) .
L
3
S
3
T
Fig..7
d) Finally, check the operation of the vice’s system. By turning the spindle (3) clockwise (CW)
the vice clamp. By turning the spindle (3) counter clockwise (CCW) the vice disengage.
- Vice disassembly is done by reversing the steps described in this User Manual.
Page 7 (of 7)
Fixing of
additional front jaw
L
3
mm/"
ks
HV 515
4-6
(0,16"-0,24")
T
2
3-5
(0,12"-0,2")
HV 516
6-8
(0,24"-0,32")
T
3
5-6
(0,2"-0,24")
∅
∅
S
3
mm/"