253462-BTG-N-1010

2

Johnson Controls Unitary Products

DIMENSIONS - (BLOWER WITH MC COILS)

NOTE: 

Power wiring may be brought into the unit through one of the knockouts in either the top or the left side panel. Multiple knockouts are provided to accommodate all 

of the electric heat and transformer accessories that are available. Use the knockouts that provide the best wire routing for the accessory being used.

DIMENSIONS

Models

Dimensions

Wiring K.O.’s

1

Refrigerant 

Connections

A

B

C

D

E

J

K

Line Size

Height

Width

Total Height

Power

Control

Liquid

Vapor

MA08B

25

17-1/2

47 to 57 

Depending 

on combination

16-1/2

14-19/32

7/8 (1/2), 1-3/8(1)

1-23/32, (1-1/4)
1-31/32, (1-1/2)

7/8 (1/2)

MA12B

2

25

17-1/2

16-1/2

14-19/32

MA14D

25

24-1/2

23-1/2

21-19/32

MA16C

2

25

21

20

18-3/32

MA20D

2

25

24-1/2

23-1/2

21-19/32

MC18B2AH1

22

17.5

47 to 57 

Depending 

on combination

16.5

16 3/8

3/8

3/4

MC18B3XH1

22

17.5

16.5

16 3/8

3/8

3/4

MC18B4EH1

22

17.5

16.5

16 3/8

3/8

3/4

MC24B2AH1

26.5

17.5

47 to 57 

Depending 

on combination

16.5

16 3/8

3/8

3/4

MC24B3XH1

26.5

17.5

16.5

16 3/8

3/8

3/4

MC24B4FH1

26.5

17.5

16.5

16 3/8

3/8

3/4

MC30B2AH1

26.5

17.5

47 to 57 

Depending 

on combination

16.5

16 3/8

3/8

3/4

MC30B3XH1

26.5

17.5

16.5

16 3/8

3/8

3/4

MC30B4EH1

26.5

17.5

16.5

16 3/8

3/8

3/4

MC30B4FH1

26.5

17.5

16.5

16 3/8

3/8

3/4

MC35B2AH1

22

17.5

47 to 57 

Depending 

on combination

16.5

16 3/8

3/8

3/4

MC35B3XH1

22

17.5

16.5

16 3/8

3/8

3/4

MC35B4FH1

22

17.5

16.5

16 3/8

3/8

3/4

MC35B4GH1

22

17.5

16.5

16 3/8

3/8

3/4

MC35B4HH1

22

17.5

16.5

16 3/8

3/8

3/4

MC35B4MH1

22

17.5

16.5

16 3/8

3/8

3/4

MC35C2AH1

22

21

20

19 7/8

3/8

3/4

MC35C3XH(1,2)

26.5/22

21

20

19 7/8

3/8

3/4

MC35C4FH1

22

21

20

19 7/8

3/8

3/4

MC35C4GH1

22

21

20

19 7/8

3/8

3/4

MC35C4HH1

22

21

20

19 7/8

3/8

3/4

MC35C4MH1

22

21

20

19 7/8

3/8

3/4

For notes, see Page 3.

AIR HANDLER

MA / MV

COIL

MC

21.5”

B

A

C

(TOTAL HEIGHT)

E

20-3/8”

J

K

A

E

10-3/8”

10-3/8”

E

D

20-1/4”

D

20-1/2”

AIR HANDLER TOP (All Models)

AIR HANDLER BOTTOM OPENING

COIL BOTTOM OPENING

Summary of Contents for MA

Page 1: ...aluminum fins to provide high heat transfer and long lasting quality The MC multi position coils may be used for upflow downflow and horizontal left or right applications Coil cabinets are insulated...

Page 2: ...16 5 16 3 8 3 8 3 4 MC18B4EH1 22 17 5 16 5 16 3 8 3 8 3 4 MC24B2AH1 26 5 17 5 47 to 57 Depending on combination 16 5 16 3 8 3 8 3 4 MC24B3XH1 26 5 17 5 16 5 16 3 8 3 8 3 4 MC24B4FH1 26 5 17 5 16 5 16...

Page 3: ...17 5 16 5 16 3 8 3 8 7 8 MC43B4KH1 26 5 17 5 16 5 16 3 8 3 8 7 8 MC43B4MH1 26 5 17 5 16 5 16 3 8 3 8 7 8 MC43C2CH1 26 5 21 20 19 7 8 3 8 7 8 MC43C3XH1 26 5 21 20 19 7 8 3 8 7 8 MC43C4GH1 26 5 21 20 19...

Page 4: ...4 33 3 29 4 24 3 75 62 28 9 24 6 21 7 19 6 70 57 25 1 23 3 21 7 19 6 MC60D H 1275 85 72 53 7 48 4 43 5 37 5 80 67 43 0 38 0 33 3 27 7 75 62 33 1 28 1 24 5 22 4 70 57 28 8 26 5 24 5 22 4 MC62D H 1450...

Page 5: ...K 1PF0602BK 1PF0604BK 1PF0604BK 1PF0604BK Shipping Operating Weight lbs 90 84 90 84 90 84 97 91 97 91 97 91 Full Cased A Type Multi Postion Model Application Refrig Conn Types Face Area Sq Ft Rows Dee...

Page 6: ...MC43C4KH1 4K 75 MC43C4MH1 4M 75 MC48C3XH1 Cooling Heat Pump Sweat 5 35 3 12 2 22 x 17 5 1 x 0 866 3 8 Enhanced None 82 MC48C2CH1 2C 82 MC48C4FH1 4F 82 MC48C4HH1 4H 82 MC48C4JH1 4J 82 MC48C4KH1 4K 82 M...

Page 7: ...7 9 8 13 4HK16501506 0 5 Med 10 8 14 4 36 9 49 1 3 6 4 8 7 2 9 6 10 8 14 4 4HK16501806 0 5 Hi 13 2 17 6 45 1 60 1 3 3 4 4 6 6 8 8 13 2 17 6 4HK16502006 0 5 Hi 14 4 19 2 49 2 65 5 3 6 4 8 7 2 9 6 14 4...

Page 8: ...HK 6500806 31 3 35 60 41 00 40 45 8 8 4HK 6501006 40 0 45 08 51 88 50 60 8 6 4HK16501306 54 2 60 4 69 6 70 70 4 4 MA12B 4HK 6500506 20 0 25 79 29 38 30 30 10 10 4HK 6500806 31 3 37 98 43 50 40 45 8 8...

Page 9: ...01046 17 4 20 12 MA16CN41 4HK06501046 17 8 25 10 4HK06501546 24 9 25 10 MA20DN41 4HK06501046 19 1 25 10 4HK06501546 26 3 30 8 4HK06502946 48 0 50 8 ELECTRICAL DATA For Multi Source Power Supply Copper...

Page 10: ...ircuit Breaker or Time Delay fuse Minimum Wire Size A W G 60 Hertz 60 Hertz 208V 230V 208V 230V MA08BN21 1 4 1 5 1 8 1 9 15 14 MA12BN21 2 1 3 5 2 6 3 0 15 14 MA14DN21 3 3 2 4 4 1 4 4 15 14 MA16CN21 3...

Page 11: ...NG 208 230 1 60 NOTE USE ONLY COPPER CONDUCTORS TERMINAL BLOCK TERMINAL BLOCK MAY BE 1 2 OR 3 CIRCUIT BREAKERS MAY BE 1 2 OR 3 CIRCUIT BREAKERS JUMPER BAR CONNECT LEADS WITH WIRE NUTS TYPICAL ALL HEAT...

Page 12: ...If an electric heat accessory which is rated for greater than zero clearance to combustible surfaces is installed in these air handlers in the downflow operating posi tions on a combustible floor one...

Page 13: ...ENUM WITH 1 FLANGES FIBERGLASS INSULATION FIBERGLASS TAPE UNDER FLANGE COMBUSTIBLE FLOOR BASE ACCESSORY A B B A AIR HANDLER DEPTH FRONT FLOOR 1 10 47 64 PLENUM 12 1 2 FLOOR OPENING APPROX 1 2 CLEARANC...

Page 14: ...Board to YES position if Humidistat is used 3 MODE Jumper on AH control board should be set to HP for heat pumps 4 To change quantity of heat during HP defrost cycle Reverse connections at W1 W2 on A...

Page 15: ...1 1407 1276 995 852 N A Med 1487 1462 1412 1356 1280 1210 1087 795 726 N A Low 1381 1353 1292 1225 1186 1057 863 780 669 N A MC62D High 1746 1699 1655 1579 1486 1399 1264 1093 796 581 Med 1486 1442 13...

Page 16: ...1162 1112 1074 975 817 737 625 493 358 MC60D High 1545 1490 1463 1378 1337 1231 1115 850 739 572 Med 1266 1248 1207 1140 1101 1005 839 687 564 469 Low 1192 1186 1126 1067 992 842 740 638 507 347 MC62...

Reviews: