Control Center Setup
Printer Setup
Access Level Required:
OPERATOR
Using the COMMS Screen, the Control Center must be
configured to transmit data in the same format as the
Printer is configured to receive the data. The following
values must be entered.
•
Baud Rate - Set as desired. Value selected must be
the same as Printer configuration above.
•
Data Bits - 8
•
Parity - None
•
Stop Bits - 1
YORK A JOHNSON CONTROLS COMPANY
UNIT MODEL < >
SERIAL NUMBER < >
<DATE>, <HOUR>
TOTAL OPERATING HOURS < > [HOURS]
LATEST RUN TIME < > [DAYS, HOURS, MINUTES]
SOFTWARE VERSION < >
- O P E R A T I N G D A T A R E P O R T -
SYSTEM STATUS < >
CONTROL STATUS < >
SYSTEM DETAILS < >, < >, < >
RETURNING CHILLED LIQUID TEMPERATURE............ < >
REFRIGERANT TEMPERATURE........................................ < >
REFRIGERANT TEMPERATURE........................................ < >
ADC LINE TEMPERATURE................................................. < >
STRONG SOLUTION TEMPERATURE............................... < >
STRONG SOLUTION CONCENTRATION.......................... < >
SOLUTION TEMPERATURE LEAVING STS...................... < >
REFRIGERANT FROM CONDENSER TEMEPERATURE.... < >
MIN SOLUTION TEMP TO CRYSTALLIZE........................ < >
RETURNING COOLING LIQUID TEMPERATURE........... < >
LEAVING COOLING LIQUID TEMPERATURE................. < >
ENTERING HOT WATER TEMPERATURE......................... < >
STEAM TEMPERATURE IN................................................. < >
STEAM PRESSURE............................................................... < >
MAX ALLOWED LOADING................................................ < >
CONTROL VALVE POSITION [%]....................................... < >
GENERATOR SHELL PRESSURE........................................ < >
LEAVING CHILLED LIQUID SETPOINT............................ < >
REMOTE TEMP SETPOINT RANGE................................... < >
REMOTE LOAD LIMIT......................................................... < >
AUTOPURGE 7 DAY COUNTER......................................... < >
AUTOPURGE TOTAL COUNTER........................................ < >
PURGE TANK PRESSURE.................................................... < >
PURGE PUMP PRESSURE.................................................... < >
PULLDOWN SETPOINT TIME............................................. < >
PULLDOWN SETPOINT START.......................................... < >
PULLDOWN SETPOINT STOP............................................. < >
CHILLED LIQUID PUMP RUN CONTACTS (ON/OFF)..... < >
CONDENSER LIQUID PUMP RUN CONTACTS (ON/OFF)... < >
CHILLED LIQUID FLOW SWITCH (OPEN/CLOSE)......... < >
CONDENSER LIQUID FLOW SWITCH (OPEN/CLOSE).. < >
REFRIGERANT PUMP (ON/OFF)........................................ < >
SOLUTION PUMP (ON/OFF)................................................ < >
ABSORBER PUMP (ON/OFF) -IF FRANKLIN-.................. < >
GENERATOR PUMP (ON/OFF) -IF FRANKLIN-................ < >
REFRIGERANT LEVEL SWITCH 1F (OPEN/CLOSE)....... < >
REFRIGERANT LEVEL SWITCH 3F (OPEN/CLOSE)....... < >
STABILIZER REFRIGERANT SOLENOID VALVE 2SOL
(OPEN/CLOSE)....................................................................... < >
REFRIGERANT LEVEL SOLENOID VALVE 3SOL
(OPEN/CLOSE)....................................................................... < >
MOTOR COOLANT SOLENOID VALVE 4SOL
(OPEN/CLOSE) -IF FRANKILN-.......................................... < >
REV. 1.0 2008
FIGURE 20 –
SAMPLE PRINTOUT
(OPERATING DATA)