036-21606-001 Rev. A (0804)

Unitary Products Group

7

NOTES

Summary of Contents for PV8

Page 1: ...S Two stage heating operation includes Two stage gas valve Two stage inducer operation Variable speed ECM blower operation Provides increased comfort level very quiet unit opera tion Field Selectable delay timer allows two stage operation w single stage thermostat Acoustically insulated blower compartment for reduced blower sound level Compact easy to install ideal height 40 cabinet Blower off del...

Page 2: ...Dimension A B C D PV8A12 N L 080UH11 1200 A 14 1 2 13 1 4 10 1 8 10 1 8 PV8B16 N L 100UH11 1600 B 17 1 2 16 1 4 15 1 4 11 5 8 PV8C20 N L 100UH11 2000 C 21 19 3 4 16 5 8 13 3 8 PV8C20 N L 120UH11 2000 C 21 19 3 4 16 5 8 13 3 8 HORIZONTAL VENTING MUST USE FIELDS CONTROL MODELS SWG 4Y OR TJERENLAND MODEL GPAK JT FIELD SUPPLIED POWER VENTING KITS Heating Input Heating Input Furnace Airflow Horizontal ...

Page 3: ... 100 65 80 53 2000 21 80 0 40 70 40 70 PV8C20 N L 120UH11 120 78 96 64 2000 21 80 0 35 65 35 65 MODEL Input BTU H High Low Output BTU H High Low Max Outlet Air Temp Blower Blower Size Unit Amps Max Fuse Size Min Wire Size Operatio n Weight F Hp Amps In Lbs PV8A12 N L 080UH11 80 59 64 48 175 1 2 7 7 10 x 8 9 0 20 14 117 PV8B16 N L 100UH11 100 65 80 53 170 3 4 9 6 10 x 10 12 0 20 14 128 PV8C20 N L 1...

Page 4: ...910 A C 1575 880 1630 820 C B 1440 830 1485 760 B C 1325 760 1355 720 D B 1410 820 1465 745 C A 1190 725 1210 650 D A 1245 745 1260 695 C C 1065 690 1080 595 D C HIGH LOW HEAT CFM INPUT High Fire 60 000 Low Fire 39 000 INPUT High Fire 80 000 Low Fire 52 000 JUMPER SETTINGS CFM CFM High Low High Low COOL Tap ADJ Tap 1315 880 1490 990 A Any 1185 795 1350 900 B Any 1075 720 1240 820 C Any 990 665 114...

Page 5: ...ystem static is 0 58 w c To determine the system airflow complete the following steps Obtain the airflow values at 0 50 w c 125 Pa 0 60 w c 150 Pa ESP Airflow 0 50 2125 CFM 60 17 m3 min Airflow 0 60 2035 CFM 57 62 m3 min Subtract the airflow 0 50 w c 125 Pa from the airflow 0 60 w c 150 Pa to obtain airflow difference 2035 2125 90 CFM 2 55 m3 min Subtract the total system static from 0 50 w c 125 ...

Page 6: ... ALTITUDE PRESSURE SWITCHES These accessory kits may be used to convert units for high altitude operation Conversion must be made by qualified dis tributor or dealer personnel 1PS0313 HIGH ALTITUDE PRESSURE SWITCH KIT DOES NOT INCLUDE ORIFICES FOR APPLICATION INFORMATION SEE FORM 035 14461 000 1PS0314 FIELD INSTALLED ACCESSORIES ELECTRICAL MODEL NO DESCRIPTION USED WITH 2ET0770010124 THERMOSTAT Tw...

Page 7: ...036 21606 001 Rev A 0804 Unitary Products Group 7 NOTES ...

Page 8: ... to change without notice Printed in U S A 036 21606 001 Rev A 0804 Copyright by York International Corp 2004 All rights reserved Supersedes Nothing Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...