background image

TECHNICAL GUIDE

AFFINITY 

MODELS: PV9

GAS-FIRED
CONDENSING / HIGH EFFICIENCY 
TWO STAGE VARIABLE 
UPFLOW FURNACES

UP TO 94% AFUE

NATURAL GAS
40 - 120 MBH INPUT

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

036-21584-002 Rev. A (1205)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.

FEATURES

• Two stage heating operation includes:

- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation

• Provides increased comfort level & very quiet unit opera-

tion

• Adjustable delay timer allows two stage operation with 

single stage thermostat

• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• May be installed as either two-pipe (sealed combustion) 

or single pipe vent (using indoor combustion air)

• Top intake & vent connection allows installation in narrow 

locations.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-

grade stainless steel.

• Timed on, adjustable off blower capability for maximum 

comfort.

• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance 

or service.

• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• ClimaTraK comfort system allows dealer to customize 

comfort settings based on regional location.

Summary of Contents for PV9A12N040UP11

Page 1: ...gas valve Two stage inducer operation Variable speed ECM blower operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code dis...

Page 2: ...TTOM IMAGE RETURN END TOP IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O CABINET AND DUCT DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in PV9A12N040UP11 1200 A 14 1 2 13 1 2 12 1 8 6 1 4 PV9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9C16N080UP11 1600 C ...

Page 3: ...om two sides or one side plus bottom ELECTRICAL AND PERFORMANCE DATA Models Input High Low Output High Low Nominal Airflow Cabinet Width Total Unit AFUE Air Temp Rise MBH MBH CFM In Amps F PV9A12N040UP11 40 26 38 24 1200 14 1 2 9 94 0 35 65 PV9B12N060UP11 60 39 56 36 1200 17 1 2 9 93 2 40 70 PV9B12N080UP11 80 52 75 49 1200 17 1 2 9 92 5 45 75 PV9C16N080UP11 80 52 75 49 1600 21 12 92 8 45 75 PV9C20...

Page 4: ... 1490 920 C A 1250 790 1290 790 D A 1310 810 1360 840 C C 1090 690 1140 690 D C HIGH LOW HEAT CFM 40 000 INPUT 3 Ton 60 000 INPUT 3 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1045 740 1110 710 A Any 905 645 960 640 B Any 825 595 870 600 C Any 765 590 830 570 D Any 80 000 INPUT 3 Ton 80 000 INPUT 4 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1330 880 1490 990 ...

Page 5: ...d upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static 5 If total system static matches a ESP value in the airflow table i e 0 20 0 60 etc the system airflow corre sponds to the intersection of the ESP column and Model Blower Speed row FILTER SIZES Input Output BTU H CFM Cabinet Size Side Return Filter in Bottom Retur...

Page 6: ...ight O Reversing Valve Energized in Cool TWO STAGE AIR CONDITIONING Comfort Alert Interface HUM Dehumidification Open on Humidity Rise C 24 Volt Common C 24 Volt Common R 24 Volt Hot W2 Second Stage Heat G Fan Y2 Second Stage Cool E W1 First Stage Heat RC 24 Volt Hot Cool XFMR Y1 First Stage Cool R 24 Volt Hot Y Y2 Single Second Stage Cool Y2 Second Stage Cool Y First Stage Cool Y2 Second Stage Co...

Page 7: ...2 Delay on furnace to OFF HM Humidistat BSG Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Heat W Auxiliary Heat Y2 Second Stage Heat Cool DHM Dehumidistat HUM Dehumidification Open on Humidity Rise Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y 2 O Reversing Valve Energized in Coo...

Page 8: ...SIDE RETURN FILTER RACK 1SF0101 Fits all cabinet sizes Attaches to side of furnace cabinet in side return applications Holds any 16x25x1 permanent or disposable filter SIDE RETURN FILTER 1SR0302 All Models 1SR0200 All Models BOTTOM RETURN FILTER 1BR0114 or 1BR0214 For 14 1 2 cabinets 1BR0117 or 1BR0217 For 17 1 2 cabinets 1BR0121 or 1BR0221 For 21 cabinets 1BR0124 or 1BR0224 For 24 1 2 cabinets IN...

Reviews: