Unitary Products Group

550.39-N4YI

TABLE OF CONTENTS

General................................................................................1

Reference ............................................................................1

Inspection ............................................................................1

Nomenclature ......................................................................2

INSTALLATION

Limitations ...........................................................................3

Location ...............................................................................3

Clearances ..........................................................................4

Rigging and Handling ..........................................................4

Vertical/horizontal Installation ..............................................4

Duct Connections ................................................................4

Refrigerant Mains ................................................................5

Drain Connection.................................................................6

Supply Air Blower Adjustment .............................................6

Power and Control Wiring..................................................11

MAINTENANCE

Filters.................................................................................12

Evaporator Coil..................................................................12

Lubrication .........................................................................12

Drain Pan ..........................................................................12

Belts...................................................................................12

TABLES

No.

Description

Page

1

Unit Application Data............................................ 3

2

Physical Data ....................................................... 5

3

Supply Air Blower Motor Pulley Adjustment......... 7

4

Blower Performance............................................. 8

5

Accessory Static Resistance (IWG/pA) ................ 9

6

Electrical Data ...................................................... 9

7

Blower Motor and Drive Data ...............................11

FIGURES

No.

Description

Page

1

Unit Suspension Mounting (Horizontal)................ 3

2

Vertical and Horizontal Appplication..................... 4

3

Supply Air Duct Connection ................................. 4

4

Electric Heater Accessory .................................... 4

5

Recommended Drain Piping ................................ 6

6

Typical Motor Mounting Assembly ....................... 7

7

Pressure Drop Across Dry Coil vs Supply Air ...... 7

8

Hole Locations (Pressure Drop Readings)........... 7

9

Unit Dimensions and Clearances.........................10

10

Typical Field Wiring (Cooling only).......................11

K

4

E

U

5

0

2

A

PRODUCT NOMENCLATURE

PRODUCT GENERATION

4,5 = Design Level

PRODUCT CATEGORY

= Split-System Evaporator Blower with

Motor and Drive

PRODUCT IDENTIFIER

EU = Evaporator Blower Unit

VOLTAGE CODE

50 = 380/415-3-50

NOMINAL COOLING

CAPACITY

090 = 90 Mbh (26.36kW)
120 = 120 Mbh (35.13kW)

FACTORY INSTALLED HEAT

A = Not Applicable

1

0

Summary of Contents for SUNLINE K4EU120A50A

Page 1: ...nt parts on this equipment All forms may be ordered from Publications Distribution Center Unitary Products Group P O Box 1592 York PA 17405 INSPECTION As soon as a unit is received it should be inspec...

Page 2: ...pA 9 6 Electrical Data 9 7 Blower Motor and Drive Data 11 FIGURES No Description Page 1 Unit Suspension Mounting Horizontal 3 2 Vertical and Horizontal Appplication 4 3 Supply Air Duct Connection 4 4...

Page 3: ...m or they can be supported by metal or wooden beams Units being installed horizontally can be suspended from above Four 3 8 9 5mm weld nuts are provided in the unit frame to accommodate hanger rods Kn...

Page 4: ...designed and installed in accordance with applicable national and or local codes Refer to Figure 3 for suggested method of connecting supply air ductwork Ducts should be sized no smaller than the duct...

Page 5: ...has no leaks and proceed with the installation Make sure the refrigerant in the lines has been recovered then drill a small hole through the discs to prevent any internal pres sure from blowing them o...

Page 6: ...be determined from the blower perform ance in Table 4 Knowing the required blower RPM and the blower motor HP the setting turns open for the supply air motor pulley can be determined from Table 3 Eac...

Page 7: ...G Failure to properly adjust the total system air quan tity can result in extensive blower damage After readings have been obtained remove the tubes and seal up the drilled holes in the side panel wit...

Page 8: ...FORMANCE1 CFM BLOWE R SPEED RPM AIRFLOW ESP2 IWG OUTPUT BHP INPUT kW ESP2 IWG OUTPUT BHP INPUT kW ESP2 IWG OUTPUT BHP INPUT kW ESP2 IWG OUTPUT BHP INPUT kW ESP2 IWG OUTPUT BHP INPUT kW 3200 3600 4000...

Page 9: ...STATIC PRESSURE DROP RESISTANCE IWG pA BLOWER CFM m3 s 3200 1 5 3600 1 7 4000 1 9 4400 2 1 4800 2 3 Electric Heat 10 kW 0 02 5 0 0 02 5 0 0 03 7 4 0 03 7 4 0 04 10 0 16 kW 0 03 7 4 0 04 10 0 0 05 12 4...

Page 10: ...access if the piping connections are made on the opposite side of the unit Allow enough clearance to trap the condensate drain line ACCESSORIES ELECTRIC HEATER Add 15 381mm to Unit Height when using 1...

Page 11: ...KEU090 11 2 1 1 650 850 3 4 4 4 86 112 7 8 22 2 7 5 190 1 25 A37 38 3 973 KEU120 2 1 5 700 910 3 4 4 4 86 112 7 8 22 2 7 0 178 1 25 A37 38 3 973 TABLE 7 BLOWER MOTOR AND DRIVE DATA All motors are 1450...

Page 12: ...the filter access panel EVAPORATOR COIL Do not allow dirt to accumulate on the evaporator coil or other parts of the evaporator air circuit Clean as often as necessary to assure good system performan...

Reviews: