Johnson Controls Ducted Systems

MECHANICAL SPECIFICATIONS

MANUFACTURE AND CERTIFICATIONS

• Units shall be manufactured in an ISO 9001 certified facility.

• Units shall be certified by CSA to UL 1995 / CSA 22.2 and

performance certified to ANSI/AHRI Standard 210/240.

• Units shall be sound tested according to ANSI/AHRI Stan-

dard 270.

• Certified matched system ratings will be available for down-

load from the AHRI online directory at www.ahridirectory.org

• Unit packaging shall be marked, “Assembled in the USA”

UNIT APPLICATION

• Units shall be approved for cooling operation between 50ºF

and 120ºF without modification.

• Units shall be approved for linesets up to 200 feet equivalent

length without modification.

• Units shall be approved for installation within 6 inches of a

flat vertical wall without modification, according to the
instructions in the technical literature.

• Units shall be certified for seismic applications in accordance

with CBC 2007 and IBC 2006.

• Units shall be designed to 72dBA or less to minimize sound

pollution.

UNIT ACCESS

• Units shall have a fan guard that can be removed inde-

pendently of the cabinet for access to the condenser coil.

• Units shall have blow-through airflow for the condensing coil.

• Units shall have a separate compartment for electrical con-

trols that can be accessed without disturbing the unit airflow.

UNIT CONSTRUCTION

• Units shall be shipped completely wired, piped and assem-

bled. Wiring pigtails shall be provided for field control wiring
connections. Service valves shall be provided for field refrig-
erant line connections.

• Units shall be factory leak checked, run tested, and shipped

with a holding charge of R-410A refrigerant.

• Unit cabinet components shall be G90 equivalent steel fin-

ished with powder-coat paint rated at a minimum of 1,000
hours under ASTM B117 testing.

• Unit base pan shall be stamped G90 equivalent steel fin-

ished with powder-coat paint rated at a minimum of 1,000
hours under ASTM B117 testing.

• Units shall have a factory installed filter drier for faster instal-

lation and improved system reliability.

• Units shall be constructed with a high pressure switch and a

low pressure switch for system protection.

UNIT COMPONENTS

• Compressor shall be hermetic with internal electrical over-

load protection and internal overpressure protection.

• Compressor shall be mounted on rubber vibration isolators

that do not require the removal of transportation clips or
brackets.

• Units shall be constructed with scroll compressors.

• Outdoor fan shall be direct drive with horizontal air dis-

charge.

• Outdoor fan shall be direct drive with swept-wing blades for

low sound levels.

• Outdoor coil shall be air cooled and constructed of zinc-

coated aluminum microchannel construction for small size
and low weight.

UNIT WARRANTIES

• Unit manufacturer shall provide a 10-Year compressor war-

ranty without a requirement for unit registration.

• Unit manufacturer shall provide a 5-Year parts warranty with-

out a requirement for unit registration.

Summary of Contents for TCHE Series

Page 1: ...lly anywhere on the ground roof balcony or mounted to an outside wall When installation footprint is lim ited these units can be stacked two high using the approved stacking kit FEATURES Performance O...

Page 2: ...TING HOLE GRAPHIC 21 TYPICAL FIELD WIRING 21 PERFORMANCE DATA 2 TON 22 PERFORMANCE DATA 3 TON 28 PERFORMANCE DATA 4 TON 30 NOMENCLATURE BRAND T T Factory Branded PRODUCT TYPE C C Air Conditioner US No...

Page 3: ...Hard Start Kit part number for each model No No No Fan Diameter Inches 23 23 23 Fan Motor Rated HP 1 4 1 4 1 4 Rated Load Amps 1 3 1 3 1 3 Nominal RPM 850 850 850 Nominal CFM 3200 3200 3050 Coil Face...

Page 4: ...ze Record the charge adjustment made to match the Charging Chart 6 Permanently stamp the unit data plate with the TOTAL SYSTEM CHARGE defined as follows TOTAL SYSTEM CHARGE Base Charge as shipped char...

Page 5: ...17 5 CF CM30B 800 24 00 18 70 16 00 13 00 TCHE24S41S1 MVC08BN21 17 5 CF CM36B 800 24 00 18 90 16 00 13 00 TCHE24S41S1 MVC12BN21 17 5 CF CM30B 875 24 00 19 20 16 00 13 00 TCHE24S41S1 MVC12BN21 17 5 CF...

Page 6: ...S41S1 TL9E060B12UH11 17 5 CF CM CU30B 675 24 0 17 7 15 50 12 75 TCHE24S41S1 TL9E060B12UH11 17 5 CF CM CU36B 650 24 0 17 6 15 75 13 00 TCHE24S41S1 TL9E060B12UH11 17 5 CF CM CU36C 700 24 0 17 9 15 75 13...

Page 7: ...F CM CU36B 700 24 0 17 9 15 75 13 00 TCHE24S41S1 TM8V060A12MP12C 14 5 CF CM36A 725 24 0 18 3 15 50 12 75 TCHE24S41S1 TM8V080B12MP11C 17 5 CF CM CU30B 775 24 0 18 4 15 50 12 75 TCHE24S41S1 TM8V080B12MP...

Page 8: ...8 18 9 14 50 12 25 TCHE24S41S1 TM8X100C20MP11 21 0 CF CM30C 825 23 8 18 3 14 50 12 25 TCHE24S41S1 TM8X100C20MP11 21 0 CF CM36D 825 24 0 19 1 14 50 12 25 TCHE24S41S1 TM8X120C20MP11 21 0 CF CM CU30D 82...

Page 9: ...0B12MP12 17 5 CF CM CU36B 750 24 0 18 3 15 75 13 00 TCHE24S41S1 TM9E060B12MP12 17 5 CF CM CU36C 750 24 0 18 3 15 50 12 75 TCHE24S41S1 TM9E060B12MP12 17 5 CF CM CU42C 750 24 0 18 3 15 75 13 00 TCHE24S4...

Page 10: ...15 75 13 00 TCHE24S41S1 TM9V080B12MP12C 17 5 CF CM CU30B 800 24 0 18 7 15 75 13 00 TCHE24S41S1 TM9V080B12MP12C 17 5 CF CM CU36B 800 24 0 19 0 15 75 13 00 TCHE24S41S1 TM9V080B12MP12C 17 5 CF CM CU36C 8...

Page 11: ...S1 TMLE060A12MP11 14 5 CF42B 825 24 0 19 1 16 00 13 00 TCHE24S41S1 TMLE080B12MP11 17 5 CF CM CU30B 725 24 0 18 1 15 75 13 00 TCHE24S41S1 TMLE080B12MP11 17 5 CF CM CU36B 725 24 0 18 3 16 00 13 00 TCHE2...

Page 12: ...75 24 0 19 6 16 00 13 00 TCHE24S41S1 TMLV100C16MP11C 21 0 CF CM CU30D 900 24 0 19 1 15 00 12 50 TCHE24S41S1 TMLV100C16MP11C 21 0 CF CM CU36C 875 24 0 19 4 15 25 12 75 TCHE24S41S1 TMLV100C16MP11C 21 0...

Page 13: ...1 0 CF CM36D 950 24 0 20 4 16 00 13 00 TCHE24S41S1 TP9C100C16MP12C 21 0 CF CM CU30D 825 24 0 18 6 15 75 13 00 TCHE24S41S1 TP9C100C16MP12C 21 0 CF CM CU36C 850 24 0 19 1 15 50 12 75 TCHE24S41S1 TP9C100...

Page 14: ...12MP12C 17 5 CF CM CU36C 850 24 0 19 4 15 75 13 00 TCHE24S41S1 YP9C080B12MP12C 17 5 CF CM30C 725 24 0 18 1 15 75 13 00 TCHE24S41S1 YP9C080B12MP13C 17 5 CF CM CU30B 800 24 0 18 7 15 75 13 00 TCHE24S41S...

Page 15: ...0 CF CM CU36C 875 24 0 19 6 16 00 13 00 TCHE24S41S1 YPLC100C16MP13C 21 0 CF CM CU36D 875 24 0 19 4 15 25 12 75 TCHE24S41S1 YPLC100C16MP13C 21 0 CF CM30C 875 24 0 19 2 16 00 13 00 TCHE24S41S1 YPLC100C1...

Page 16: ...00 12 50 TCHE36S41S1 TMLV080C16MP11C 21 0 FC38C 1200 35 6 27 0 15 10 12 50 TCHE36S41S1 TMLV080C16MP12C 21 0 FC38C 1050 35 4 25 8 15 75 13 25 TCHE36S41S1 TMLV100C16MP11C 21 0 FC38C 1200 35 6 27 0 15 1...

Page 17: ...TM8E100C20MP11 21 0 FC49D 1225 45 5 32 4 15 00 12 50 TCHE48S41S1 TM8E120C16MP11 21 0 FC49D 1275 46 0 33 2 15 00 12 25 TCHE48S41S1 TM8E120C20MP11 21 0 FC49D 1250 45 5 32 6 15 00 12 50 TCHE48S41S1 TM8E...

Page 18: ...41S1 TP9C120D20MP12C 24 5 FC49D 1375 46 0 33 8 15 10 12 50 TCHE48S41S1 TP9C120D20MP13C 24 5 FC49D 1200 45 5 32 0 15 10 12 50 TCHE48S41S1 TPLC080C16MP12C 21 0 FC49D 1425 46 0 34 4 14 25 12 00 TCHE48S41...

Page 19: ...d for units with recip compressors when applied with indoor TXV and for all units when applied with long linesets or low ambient kits May be factory installed on select AC HP units see Physical Electr...

Page 20: ...completely wired piped and assem bled Wiring pigtails shall be provided for field control wiring connections Service valves shall be provided for field refrig erant line connections Units shall be fa...

Page 21: ...LL OUTDOOR WIRING MUST BE WEATHERPROOF CAN BE STACKED TWO HIGH WITH APPROVED STACKING KIT AIRFLOW DIRECTION 28 06 7 50 18 73 LARGE CABINET ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC A...

Page 22: ...3 5 22 5 21 6 18 5 17 7 14 3 24 0 23 9 20 3 19 1 15 1 K W 1 31 1 31 1 64 1 35 1 3 1 38 1 38 1 54 1 4 1 38 1 45 1 45 1 45 1 45 1 45 65 55 T C 24 3 23 3 26 2 25 5 27 1 24 4 24 3 25 6 26 2 27 9 24 4 25 3...

Page 23: ...060B12UH11 CF CM CU30B 1 00 1 01 0 96 TL9E060B12UH11 CF CM CU36B 1 00 1 01 0 94 TL9E060B12UH11 CF CM CU36C 1 00 1 02 0 94 TL9E060B12UH11 CF CM CU42C 1 00 1 02 0 94 TL9E060B12UH11 CF CM30C 1 00 1 02 0...

Page 24: ...1 03 0 93 TM8X100C16MP11 CF CM CU36C 1 00 1 02 0 94 TM8X100C16MP11 CF CM30C 1 00 1 02 0 94 FURNACE MULTIPLIERS 2 TON Continued Furnaces Coil T C S C KW TM8X100C16MP11 CF CM36D 1 00 1 05 0 94 TM8X100C...

Page 25: ...36B 1 00 1 09 0 96 TM9V080B12MP11C CF CM CU36C 1 00 1 11 0 94 FURNACE MULTIPLIERS 2 TON Continued Furnaces Coil T C S C KW TM9V080B12MP11C CF CM30C 1 00 1 03 0 94 TM9V080B12MP12C CF CM CU30B 1 00 1 07...

Page 26: ...CU30D 1 00 1 09 0 98 TMLV100C16MP11C CF CM CU36C 1 00 1 11 0 96 FURNACE MULTIPLIERS 2 TON Continued Furnaces Coil T C S C KW TMLV100C16MP11C CF CM30C 1 00 1 10 0 94 TMLV100C16MP11C CF CM36D 1 00 1 12...

Page 27: ...0 94 YP9C080B12MP13C CF CM CU30B 1 00 1 07 0 94 YP9C080B12MP13C CF CM CU36B 1 00 1 09 0 94 YP9C080B12MP13C CF CM CU36C 1 00 1 11 0 94 FURNACE MULTIPLIERS 2 TON Continued Furnaces Coil T C S C KW YP9C0...

Page 28: ...34 3 29 0 28 3 22 0 35 7 37 0 31 1 30 1 22 8 K W 1 89 1 91 1 88 1 90 1 92 1 96 1 98 1 96 1 98 2 00 2 04 2 06 2 05 2 06 2 09 65 55 T C 33 2 35 7 35 7 38 7 41 4 34 7 36 8 36 7 39 7 42 2 36 2 37 9 37 7...

Page 29: ...01 0 97 0 98 TMLE080C20MP11 FC38C 1 01 1 01 0 98 TMLE100B12MP11 FC38C 1 01 0 97 1 00 TMLE100C16MP11 FC38C 1 01 0 97 0 98 TMLE100C20MP11 FC38C 1 01 1 01 0 98 TMLE120C16MP11 FC38C 1 01 0 97 0 98 TMLE12...

Page 30: ...40 6 34 8 31 9 26 3 45 8 42 4 36 1 32 9 27 0 K W 2 46 2 48 2 48 2 50 2 55 2 54 2 56 2 56 2 58 2 64 2 62 2 64 2 64 2 67 2 73 65 55 T C 43 7 46 1 46 3 48 5 51 2 45 1 47 1 47 3 49 4 52 0 46 6 48 2 48 3...

Page 31: ...0 96 1 00 TM9Y100C20MP11 FC49D 1 00 0 99 0 97 TM9Y120D20MP11 FC49D 0 99 0 95 0 96 TMLE080C16MP11 FC49D 0 99 0 96 0 98 TMLE080C20MP11 FC49D 0 99 0 96 0 96 TMLE100C16MP11 FC49D 1 00 0 98 0 99 TMLE100C2...

Page 32: ...o change without notice Published in U S A 5371951 YTG C 0919 Copyright 2019 by Johnson Controls All rights reserved Supersedes 5371951 YTG B 0619 York International Corp 5005 York Drive Norman OK 730...

Reviews: