Indicates a potentially hazardous situation which will result in possible injuries or
damage to equipment if proper care is not taken.
Highlights additional information useful to the technician in completing the work
being performed properly.
�
External wiring, unless specified as an optional connection in the
PDQXIDFWXUHU¶V
product line, is not to be connected inside the control cabinet. Devices such as relays,
switches, transducers and controls and any external wiring must not be installed
LQVLGH WKH PLFUR SDQHO $OO ZLULQJ PXVW EH LQ DFFRUGDQFH ZLWK -RKQVRQ &RQWUROV¶
published specifications and must be performed only by a qualified electrician.
Johnson Controls will NOT be responsible for damage/problems resulting from
improper connections to the controls or application of improper control signals.
Failure to follow this warning will void the
PDQXIDFWXUHU¶V
warranty and cause serious
damage to property or personal injury.
Summary of Contents for YCAE065X
Page 2: ......
Page 6: ...BASIC UNIT NOMENCLATURE...
Page 9: ...SECTION 1 GENERAL INFORMATION AND SAFETY INTRODUCTION QJ WKH XQLW V WARRANTY 1...
Page 12: ...High Temperature and Pressure Cleaning 4...
Page 14: ...Condenser POWER PANEL 6...
Page 15: ...ACCESSORIES OPTIONS 7...
Page 16: ...HYHO DGMXVWLQJ VSULQJ W SH PP RU VHLVPLF GHIOHFWLRQ RU 8...
Page 24: ...16...
Page 25: ...WIRING 17...
Page 26: ...Pump Start Contacts Alarm Status Contacts Remote Start Stop Contacts 18...
Page 27: ...Flow Switch Input External Interlock ILUH DODUPV LQ FDVH WKHUH V DQ HPHUJHQF FXWR 19...
Page 29: ...Power Supply Connection Single Unit Power Supply Connection Modular 21...
Page 31: ...COMMUNICATION CABLE REQUIREMENT Field Wirings YCAE065X 23...
Page 33: ...SECTION 5 TECHNICAL DATA PHYSICAL DATA 25...
Page 34: ...ELECTRICAL DATA Model YCAE065X YCAE100X YCAE130X ELECTRICAL DIAGRAM YCAE065X 26...
Page 35: ...27...
Page 36: ...YCAE100 130X 28...
Page 37: ...29...
Page 45: ...KHQ WKH ODVW FRPSUHVVRU LQ D V VWHP RQH RU W 37...
Page 51: ......
Page 52: ...RQ UP FWLRQ Q OOLQJ...
Page 53: ...EODFN...
Page 54: ......
Page 56: ...48...
Page 58: ...EXPANSION TANK 50...
Page 59: ...ModBus Protocol DEFINITIONS 51...
Page 60: ...SYSTEM SETPOINTS 52...
Page 61: ...SYSTEM PARAMETERS 53...
Page 62: ...UNIT PARAMETERS 54...
Page 63: ...81 7 3 5 0 7 56 217 55...
Page 64: ...FAULT DEFINITIONS 56...
Page 65: ...8 7 1 7 216 217 57...
Page 66: ...8 7 1 7 216 217 58...
Page 67: ...8 7 1 7 216 217 59...
Page 68: ...PRESSURE TRANSDUCER DIAGRAM Low Pressure Transducer High Pressure Transducer 60...
Page 70: ...5 35 6685 7 03 5 785 57 217 Gauge Pressure kPa Temperature C Transducer Output 62...
Page 71: ......