background image

INSTRUCTIONS PERTAINING TO A

RISK OF FIRE, ELECTRIC SHOCK, OR

INJURY TO PERSONS.

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT  REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL.

Read Instructions:

The 

Owner’s Manual should be read and understood

before operation of your unit.

 Please, save these

instructions for future reference.

Packaging:

Keep the box and packaging materials, in case the unit
needs to be returned for service.

Warning:

When using electric products, basic precautions should
always be followed, including the following:

Power Sources:

Your unit should be connected to a power source only of the
voltage specified in the owners manual or as marked on the unit.
This unit has a polarized plug. Do not use with an extension cord or
receptacle unless all three blades can be fully inserted to prevent
blade exposure. Precautions should be taken so that the grounding
scheme on the unit is not defeated.

Power Cord:

The AC supply cord should be routed so that it is unlikely that it will
be damaged. If the AC supply cord is damaged DO NOT
OPERATE THE UNIT
.

Service:

The unit should be serviced only by qualified service personnel.

INSTRUCTIONS RELATIVES AU

RISQUE DE FEU, CHOC ÉLECTRIQUE,

OU BLESSURES AUX PERSONNES.

AVIS:

 

AFIN DE RÉDUIRE LES RISQUE DE CHOC

ÉLECTRIQUE, N’ENLEVEZ PAS LE COUVERT (OU

LE PANNEAU ARRIÈRE).

  

NE CONTIENT AUCUNE

PIÈCE RÉPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN

QUALIFIÉ POUR L’ENTRETIENT.

Veuillez lire le manuel:

Il contient des informations qui devraient êtres comprises
avant l’opération de votre appareil. Conservez S.V.P. ces
instructions pour consultations ultérieures

Emballage:

Conservez la boite au cas ou l’appareil devait être
retourner pour réparation.

Warning:

Attention: Lors de l’utilisation de produits électrique,
assurez-vous d’adhérer à des précautions de bases
incluant celle qui suivent:

Alimentation:

L’appareil ne doit être branché qu’à une source d’alimentation
correspondant au voltage spécifié dans le manuel ou tel qu’indiqué
sur l’appareil. Cet appareil est équipé d’une prise d’alimentation
polarisée. Ne pas utiliser cet appareil avec un cordon de
raccordement à moins qu’il soit possible d’insérer complètement
les trois lames. Des précautions doivent êtres prises afin d’eviter
que le système de mise à la terre de l’appareil ne soit désengagé.

Cordon d’alimentation:

Évitez d’endommager le cordon d’alimentation. N’UTILISEZ PAS
L’APPAREIL
 si le cordon d’alimentation est endommagé.

Service:

Consultez un technicien qualifié pour l’entretien de votre appareil.

IMPORTANT SAFETY INSTRUCTIONS

safe_v3.doc Version 3.5 Mar 98

Summary of Contents for AudioPro AP1200

Page 1: ...bsonique 12 Commutateur de Limiteur 12 D E L Protectrice 13 Protection Contre Les Court Circuits 13 Protection du CC 13 Protection Thermique 13 Refroidissement 13 DEL d Écretage 13 Configuration de la Section de Puissance 14 Autres Détails de Conception 14 Système de Gestion Energétique 15 Fiabilité 15 Applications 15 Distorsion Harmonique Totale 16 17 Spécifications Before operating this unit ple...

Page 2: ... RISQUE DE FEU CHOC ÉLECTRIQUE OU BLESSURES AUX PERSONNES AVIS AFIN DE RÉDUIRE LES RISQUE DE CHOC ÉLECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIÈRE NE CONTIENT AUCUNE PIÈCE RÉPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIÉ POUR L ENTRETIENT Veuillez lire le manuel Il contient des informations qui devraient êtres comprises avant l opération de votre appareil Conservez S V P ces i...

Page 3: ... this amplifier Balanced Inputs Either XLR or two circuit ring tip sleeve STEREO 1 4 PHONE cords may be used Each channel s XLR input is internally paralleled with its phone input The TIP of the channel A PHONE input is connected to pin 2 of its XLR input the RING is connected to pin 3 and the SLEEVE is connected to PIN 1 PIN 2 is in phase PIN 3 is 180 degrees out of phase and PIN 1 is ground We r...

Page 4: ...m problems are an indication of improper AC wiring somewhere else in your system Don t just doctor the symptom by lifting grounds Fix the cause by making sure that the proper electrical wiring safety regulations have been adhered to The AP1200 can be configured for dual MONO STEREO or BRIDGED MONO operation via this rear panel MODE switch The following is a description of each mode Mono Channel B ...

Page 5: ...g is permitted The limiters will not only help to protect your system s horns and tweeters but will automatically make the best use of the available dynamic headroom With the limiters activated all you need to do is turn up the signal level until you start to see some clipping The limiters will make sure that you are getting the maximum clean power output at all times Setting the switch to the OUT...

Page 6: ...pair Technician Your dealer can quickly have it done for you This feature is intended to be used in fixed installations where the load is known and is not likely to change PLEASE NOTE In this non standard 4 Ohm configuration the minimum load per channel is 4 Ohms and the minimum BRIDGE load is 8 Ohms Attempting to operate into 2 Ohm loads while in the 4 Ohm configuration will cause the amplifier t...

Page 7: ...the user is often forced to find some way to connect these products to standard line outlets Due to the lower average power required by music this will sometimes work but there is the possibility that circuit breakers will trip during a performance Given enough input power the AP1200 is fully capable of delivering its rated power continuously However AP1200 s power switch is also a circuit breaker...

Page 8: ...phasis The AP1200 will drive 8 Ohm loads with better sonic purity and lower distortion than any listening amplifier we know of including those that cost much more And since the AP1200 is built to survive grueling road conditions and constant 2 ohm operation its reliability in a fixed installation running 4 or 8 ohm studio monitors is without parallel Of course what really counts is how it sounds L...

Page 9: ...the AP1200 will deliver to a typical sub woofer The 1KHz burst represents the maximum possible sine waveoutputpower TheAP1200comesfromthefactoryinitsSTANDARDCONFIGURATION However it may be modified at your dealer s service center for the non standard 4 OHM CONFIGURATION See POWER CONFIGURATION on page 5 of this manual for more details SPECIFICATIONS BOTH CHANNELS DRIVEN LOAD STANDARD CONFIGURATION...

Page 10: ...ltage unweighted DC OFFSET Less than 30 millivolts PROTECTION Fully protected DC LOAD and THERMAL COOLING Anodized AL Heatsink with DC servo controlled fan SLEW RATE Power amp 25 V uS 50 V uS in bridged mode Rise time limited to 18 V uS by input filter DAMPING FACTOR 600 20 Hz 400 Hz into 8 ohms plenty MAX OUTPUT AMPS 60 Amperes repetitive peak 30 amperes continuous into resistive loads 60 Amps pe...

Page 11: ...lit ses fonctions de façon impéccable Nous espérons que ce manuel répondera aux questions que vous pourriez avoir espérons que ce manuel répondera au question que vous pourriez avoir au sujet des caractéristiques particulières du AP 1200 Deux modèles de connecteur peuvent être utilisés pour les entrées symétriques XLR ou prise phono 1 4 à double circuit stéréo pointe couronne manchon La prise XLR ...

Page 12: ...e de signal utilisé symétrique ou assymétrique La source originale doit entrainer tous les autres Dix huit AP 1200 représentent une charge d environ 600 ohms N importe quelle source capable de fournir un niveau de 9dB à 600 ohms devrait être capable de piloter cette charge sans problème Débrancher la tresse de mise à la terre sur le panneau arrière de AP 3000 découple la masse entre le châssis et ...

Page 13: ... en dessous de 40 Hz et une augmentation de 3 6dB à 50Hz La conception du réseau à 5 pôles permet de minimiser les décalages de phase à 40 Hz Nous vous recommandons l utilisation de ce filtre en conjonction avec certains modèles de cabinet pour sous grave et tous les cabinets pleine bande Lorsque le filtre est désengagé le AP 1200 offre une réponse en fréquence stable jusqu à 20Hz avec une coupure...

Page 14: ...haud qui sort par les bouches d aération tend à s éloigner du rack Il est plus facile de tirer l air par les côtés que de la repousser par les côtés Il peut être nécessaire d installer des ventillateurs si l arrière du rack s il est obstrué S il n y a pas d obstruction aucune ventillation additionnelle n est requise Les DEL d écrêtages sur le panneau avant indiquent les excursions au delà de l ext...

Page 15: ...eptions analogues Aucun amplificateur numérique peut en faire autant La discussion qui suit implique une opération avec 120 VCA 60 Hz Tous les amplificateurs qui ont une puissance nominale au dessus de 1400 watts comptent sur le fait que la puissance moyenne requise pour reproduire la musique est considérablement en dessous de la puissance maximum que l amplificateur est capable de fournir Quelque...

Page 16: ...ne fiabilité à toute épreuve pour bien des années à venir Le AUDIOPRO AP 1200 est non seulement excellent pour les situations qui demandent un grand rendement mais il excelle aussi à reproduire la clarté des enregistrements sur disque compact où une extention dynamique considérable et un très bas taux de distortion sont nécessaires Le AUDIOPRO AP 1200 peut conduire une charge de 8 ohms avec une me...

Page 17: ...tefois être modifié à un centre de service autorisé pour opérer en configuration inhabituelle de 4 ohms pour plus d information voir la section CONFIGURATION DE LA SECTION DE PUISSANCE dans ce manuel LOAD STANDARD CONFIGURATION 4 575 650 750 750 950 1000 2 825 1050 1350 n a n a n a OHMS MIN 4 OHM CONFIGURATION BURST BURST CONT AVG 1KHz 8 325 375 400 425 500 525 100Hz CONT AVG BURST BURST 1KHz 100H...

Page 18: ...Compensation Moins de 30 millivolts Protection Pleinement protegé DC charge Thermique Refroidissement Dissipateur de chaleur interfolié avec ventillateur controlé par servo CC Vitesse de Propagation Amp de puissance 25 V USEC 50 V USec en mode en pont temps de monté limité à 18 USEC par le filtre d entrée Coéfficient D Amortissement 600 20 Hz 400 Hz à 8 ohms amplement Sortie Maximum de Courant 60 ...

Page 19: ...ate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Quality and Innovation Since 1963 Printed in Canada ...

Reviews: