background image

IMPORTANT SAFETY INSTRUCTIONS

safety-4v2.eps Aug 26/05

CAUTION

:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO

NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL.

INSTRUCTIONS PERTAINING TO A

RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS

Read Instructions

The Owner’s Manualshould be read and understood 
before operation of your unit. Please, save these instruc-
tions for future reference.

Packaging

Keep the box and packaging materials, in case the unit 
needs to be returned for service.

Warning

When using electric products, basic precautions should 
always be followed, including the following:

Power Sources

Your unit should be connected to a power source only of the voltage 
specified in the owners manual or as marked on the unit. This unit has 
a polarized plug. Do not use with an extension cord or receptacle 
unless the plug can be fully inserted. Precautions should be taken so 
that the grounding scheme on the unit is not defeated.

Hazards

Do not place this product on an unstable cart, stand, tripod, bracket or 
table. The product may fall, causing serious personal injury and serious 
damage to the product. Use only with cart, stand, tripod, bracket, or 
table recommended by the manufacturer or sold with the product. 
Follow the manufacturer’s instructions when installing the product and 
use mounting accessories recommended by the manufacturer.

The apparatus should not be exposed to dripping or splashing water; 

no objects filled with liquids should be placed on the apparatus.

Terminals marked with the “lightning bolt” are hazardous live; the 

external wiring connected to these terminals require installation by an 
instructed person or the use of ready made leads or cords.

No naked flame sources, such as lighted candles, should be 

placed on the apparatus.

Power Cord

The AC supply cord should be routed so that it is unlikely that it will be 
damaged. If the AC supply cord is damaged DO NOT OPERATE THE UNIT.

Service

The unit should be serviced only by qualified service personnel.

AVIS:

AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE,

N’ENLEVEZ PAS LE COUVERT (OU LE PANNEAU ARRIERE)

 

NE CONTIENT AUCUNE PIECE

REPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN QUALIFIE

POUR L’ENTRETIENT

INSTRUCTIONS RELATIVES AU RISQUE

DE FEU, CHOC ÉLECTRIQUE, OU

BLESSURES AUX PERSONNES

Veuillez Lire le Manuel

Il contient des informations qui devraient êtres comprises 
avant l’opération de votre appareil. Conservez S.V.P. ces 
instructions pour consultations ultérieures.

Emballage

Conservez la boite au cas ou l’appareil devait être 
retourner pour réparation.

Attention:

Lors de l’utilisation de produits électrique, assurez-vous 
d’adhérer à des précautions de bases incluant celle qui 
suivent:

Alimentation

L’appareil ne doit être branché qu’à une source d’alimentation 
correspondant au voltage spécifié dans le manuel ou tel qu’indiqué sur 
l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. 
Ne pas utiliser cet appareil avec un cordon de raccordement à moins 
qu’il soit possible d’insérer complètement les trois lames. Des 
précautions doivent êtres prises afin d’eviter que le système de mise à 
la terre de l’appareil ne soit désengagé.

Risque

Ne pas placer cet appareil sur un chariot, un support, un trépied ou une 
table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir 
des dommages importants. Utiliser seulement un chariot, un support, 
un trépied ou une table recommandés par le fabricant ou vendus avec 
le produit. Suivre les instructions du fabricant pour installer l’appareil et 
utiliser les accessoires recommandés par le fabricant.

Il convient de ne pas placer sur l’appareil de sources de flammes 

nues, telles que des bougies allumées.

L’appeil ne doit pas être exposé à des égouttements d’eau ou des 

éclaboussures et qu’aucun objet rempli de liquide tel que des vases 
ne doit être placé sur l’appareil.

Les dispositifs marqués d’une symbole “d’éclair” sont des parties 

dangereuses au toucher et que les câblages extérieurs connectés à 
ces dispositifs de connection extérieure doivent être effectivés par un 
opérateur formé ou en utilisant des cordons déjà préparés.

Cordon d’Alimentation

Évitez d’endommager le cordon d’alimentation. N’UTILISEZ PAS 
L’APPAREIL si le cordon d’alimentation est endommagé.

Service

Consultez un technicien qualifié pour l’entretien de votre appareil.

Summary of Contents for Bassmaster YBA200

Page 1: ...ara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS WEB ACCESS http www yorkville com CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Quality and Innovation Since 1963 Printed in Canada SERVICE MANUAL YBA200 ...

Page 2: ...IQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT INSTRUCTIONS RELATIVES AU RISQUE DE FEU CHOC ÉLECTRIQUE OU BLESSURES AUX PERSONNES Veuillez Lire le Manuel Il contient des informations qui devraient êtres comprises avant l opération de votre appareil Conservez S V P ces instructions pour cons...

Page 3: ...ES 2 5959 _10U 450V 20 CAP BLK EL 1 4751 1 4W 22M 5 T R RES 1 5260 _22U 50V 20 CAP T R RAD 2 EL 8 3535 10 9C 26AWG RIB 1 W LCK HDR 098 1 5958 _22U 350V 20 CAP BLK 13X25 EL 4 8741 4 40 X 1 2 PAN PH MS JS500 2 5879 100U 16V 20 CAP T R 8X7MM 2 EL 1 8842 4 X 5 16 PAN QUAD TYPE A JS500 BLK 2 5619 330U 100V 20 CAP BLK 12X25MM EL 1 8832 6 32 X 1 4 PAN PH TAPTITE JS500 40 5957 470U 350V 20 CAP BLK 30X50 E...

Page 4: ...HICKEN BEAK KNOB 14 8649 BUTTON KNOB FLAT BLACK 15 6397 JEWELED PILOT LAMP AMBER REG 16 3554 DPDT TOGGLE SW QUICK 250 17 8521 RUBBER BUMPER WITH WASHER VERYSMALL 18 8452 HANDLE RESESSED PULL BLACK PLASTIC 19 3428 8 3 18 SJT AC LINE CORD REMOVABLE 20 12AX7 12AX7 DUAL TRIODE PREAMP TUBE 21 12AU7 12AU7 DUAL TRIODE PREAMP TUBE 22 6550 6550 TETRODE OUTPUT POWER TUBE 23 4021 SPRING RETAINER FOR 6550 NOT...

Page 5: ...agram for YBA200 Scoop Mono 1 4 Range Preamp V1 A Preamp V1 B Preamp V2 A Amp In Pre Amp Out Bal Line Out Mono 1 4 0dB 6dB Channel Inputs Speaker Outputs EQ Low Mid High DESIGNED AND MANUFACTURED BY YORKVILLE SOUND On Off Gain Scoop Bright Tuner Output Mute Volume Preamp V2 B Power Amp 8 ohm 4 ohm POST EQ PRE EQ 20dB Pad Ground Lift Resonance Mono 1 4 Mono 1 4 MODEL TYPE YS1029 ...

Page 6: ...3V 220N S1 B SCOOP S1 A SCOOP C7 400V 1N C5 250V 100N R15 1 4W 220K C46 400V 22N R61 5 0W 1K8 1N750ARL D18 0W5 4V7 Q18 5104 MPSA56 TO92 3682 W12 RED B R71 1 4W 8K2 R70 1 4W 18K R108 1 4W 10K R69 1 4W 18K R59 5 0W 1K8 R65 1 0W FLMP 10R C45 400V 22N C19 100V 47P C18 100V 47P U1 A TL072CP U1 B TL072CP 8 V 4 V U1 C R32 1 4W 100K R37 1 8W FLMP 249R C54 63V 150N C14 250V 10N R18 1 4W 4K7 R24 1 4W 100K C...

Page 7: ...50V C63 220N D15 1N5262B 51V0 D16 1N5262B 51V0 C60 250V 10N D13 1N5262B 51V0 D11 1N5262B 51V0 D12 1N5262B 51V0 R94 1 4W 2K2 15V GND 15V C56 100V 100N 78V 1N5254B D20 27V0 S15 DPDT Switch C22 275V 22N W22 GRN GND 16AWG 8 3 4 5 6 7 9 2 1 T1 GRN GRN YEL GRY RED GRY RED BLK BLK V4 B C24 25V 470U C27 25V 470U W39 W38 D24 4007 C29 100V 100N R101 1 0W 10K0 V2 C C72 450V 10U R123 1 0W 10K0 R102 1 0W 10K0 ...

Page 8: ...0N 250V 25V 470U 25V 470U 10N 10K RED 47K 10K 15A 500K 10R 1 0W 249K 220N 250V 1M 1B 100K 1B 100K 22N 400V 6N8 220N 250V 10R 1 0W 10R 1 0W 820R 22U 350V 2 0W 150K 22U 350V 10K0 1 0W 120K 220K 15A 500K 15A 500K 47P 100K 15A 500K 4N7 470K YEL 5 0W 1K8 275V 22N HER508 5 0W 1K8 1 6 0 V 1 0 U 470U 350v Val Val 25V 470U 11K 10K0 1 0W 5 0W 1K8 22U 350V Val DPDT SLID BC550C 470R 1 0W RED 5 0W 1K8 5 0W 33R...

Page 9: ...rd to preamp Modified STDBY switching YBA200 22 Sept 2003 1 00p1 2nd Proto 9 Jan 2004 v1 00 fixed heatsink and made value changes M648 PCB HISTORY 10 MAR 2004 V2 00 CHNGD SKRN EYELET SAME ON BOTH SIDE OF WIRES CHNGD SKRN TUBES NOW HAVE V DESIGNATION 16 MAR 2004 V2 00 PC 6672 Change D20 from 20V0 to 27V0 zener 6426 PC 6672 Corrected colour labels on LD1 LD2 22 MAR 2004 V2 00 PC 6672 Apply masking t...

Page 10: ...EEN YEL RED ORN GRN CH1333 CH1333M Q 7 Q 4 Q 5 Q 6 C 32 C 33 YBA 200 NA AC WIRING R 60 R 56 RED BLK BRN BLUE RED BLK YEL GRN From Pre Amp to Pwr Double Ins Wires W26 W27 BLACK WHITE DBL INS WIRES YBA 200 CE SAME AS N A CH1333E ...