5
‐
■
EPDT-002g
■
5.2 Operation Method
Caution
1. While switching the cock, make sure to operate as following order.
*Switching without pulling up he cock may cause damage.
2. When switching the cock, foreign substances and scales may flow from the gap
between the cock and the main body to the outlet side.
1.
Fit the handle to hexagonal adjusting screw and turn clockwise to unlock. It may be hard to do so because
the cock and adjusting screw are tightened together. In this case, hit the handle with plastic hammer. (Do
not use iron hammer). Turn the adjusting screw clockwise one or two times.
2.
Fit the pentagon hole of the handle to the cock. (Stopper is facing downward) and switch the cock right or
left. Match the arrows on the cock and handle with the arrow end on the screen side to be used. Turn until
the handle stops by the stopper
3.
After switching, fit the adjusting screw to the hexagon hole on the handle and turn counterclockwise. When
cock and adjusting screw turn at the same time, please fix the one side with the wrench. Please tighten the
adjusting screw with provided handle.