background image

5

‐                                 

EPDT-002g

 

 

5.2 Operation Method

 

 

            Caution

 

1. While switching the cock, make sure to operate as following order.   
    *Switching without pulling up he cock may cause damage. 
2. When switching the cock, foreign substances and scales may flow from the gap 
between the cock and the main body to the outlet side.     

 
1. 

Fit the handle to hexagonal adjusting screw and turn clockwise to unlock. It may be hard to do so because 
the cock and adjusting screw are tightened together. In this case, hit the handle with plastic hammer. (Do 
not use iron hammer). Turn the adjusting screw clockwise one or two times. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
2. 

Fit the pentagon hole of the handle to the cock. (Stopper is facing downward) and switch the cock right or 
left. Match the arrows on the cock and handle with the arrow end on the screen side to be used. Turn until 
the handle stops by the stopper 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
3. 

After switching, fit the adjusting screw to the hexagon hole on the handle and turn counterclockwise. When 
cock and adjusting screw turn at the same time, please fix the one side with the wrench. Please tighten the 
adjusting screw with provided handle. 

 

 
 
 

                                                                             

 

 
 
 
 
 
 
 
 
 

 

 

 

Summary of Contents for SW-10

Page 1: ...injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents Usage of the Product 1 1...

Page 2: ...1 Specifications Nominal Size 20A 100A Application Cold and hot water oil other non dangerous fluids Maximum Pressure 1 0MPa Maximum Temperature 80 Material Body Ductile Cast Iron Cock Stainless stee...

Page 3: ...W 10 SW 10S 20A 200 100 100 126 280 292 363 180 64 5 108 135 248 12 14 R 3 4 23 9 26 7 25A 200 100 100 126 280 292 363 180 64 5 108 135 248 12 14 R 3 4 25 1 27 9 32A 205 102 5 102 5 126 280 292 363 18...

Page 4: ...andard flow velocity depend on the relative kind of fluid Standard flow velocity of fluid Fluid Standard flow velocity Water Oil 2 m s 2 4 The above chart shows the standard flow velocity of relative...

Page 5: ...and cause malfunction 10 Fluid with viscosity stick the parts and lead to malfunction of the products 11 Before connecting the product in the piping be sure to remove foreign substances and scale fro...

Page 6: ...tightened together In this case hit the handle with plastic hammer Do not use iron hammer Turn the adjusting screw clockwise one or two times 2 Fit the pentagon hole of the handle to the cock Stopper...

Page 7: ...side the pipe and remove cover 21 Leakage at outside 1 Gasket O ring 24 is damaged 2 U packing 7 is damaged 1 Replace the gasket and O ring to new one 2 The product need to be disassembled and its par...

Page 8: ...f the screen case and cover Make sure that O ring is attached properly If the O ring is not installed properly O ring may be damaged and can be result in outer leakage 2 In case O ring is damaged or d...

Page 9: ...duct Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by foreign s...

Reviews: