background image

6

‐                                 

EPDT-002g

 

6. Maintenance

 

 

6.1 Troubleshooting

 

 

Trouble

 

Cause

 

Remedy

 

Fluid does not flow.

 

1. 

Screen [22] is clogged.

 

2. 

Stop valve at inlet and outlet are 

shut-off. 

 

1. 

Disassemble and clean the screen [22].

 

2. 

Open the stop valve. 

 

3. 

Installation direction is wrong.

 

3. 

Confirm  the  arrow  on  the  product  and 

install it correctly.

 

Pressure 

loss 

is 

excessive

 

1. 

  Screen [22] is clogged. 

 

2. 

  Pressure gauge is damaged. 

 

3. 

  The nominal size is too small for 

the actual flow rate. 

 

1. 

Disassemble and clean the screen [22].

 

2. 

Replace pressure gauge. 

 

3. 

Use strainer with larger nominal size. 

 

Figure 1

 

Pressure Loss chart

 

Foreign substance is 
not removed

 

1. 

Screen [22] is damaged. 

 

1.  Disassemble  the  strainer  and  change  the 

screen [22]. In case on-off valve are installed at 
either end of the strainer, do not open the valve 
immediately since this may result in damage of 
the water hammer. 

 

Cover [21] cannot be 
removed 

upon 

changing screen. 

 

 

1. 

The  inside  of  the  product  is 

vacuum.

 

1.  Break  the  vacuum  inside  the  pipe  and 

remove cover [21].

 

Leakage at outside

 

1. 

Gasket, O-ring [24] is damaged. 

 

2. 

U-packing [7] is damaged. 

 

1. Replace the gasket and O-ring to new one. 

 

2. The product need to be disassembled and 

its part need to be replaced. Please contact us. 

 

 

6.2 Warning and caution upon inspection

 

 

If the strainer is clogged with foreign substances or scale, the fluid passage area will decrease and the fluid 
will not flow smoothly. Then it causes damage to the screen and affects the piping system. 

 

 

 

          Warning

 

1.  Prior to carrying out the maintenance and inspection, make sure that the pressure inside of the strainer 

or piping system decrease to the atmospheric pressure. Also, in case the high temperature of fluid is 
applied, leave the system cooled down until you can handle them.   
*Remaining internal pressure will cause injury or scald.   

 

1. 

When cleaning the screen, check the direction and make sure that fluid is not passing. Open the cap which 
the fluid is not passing through, remove the screen, and clean with compressed air and cleaning detergent. 

 

*Do not remove the screen by force when screen is stuck on screen case due to scale and rust. (Screen 
handle might be damaged). 

 

 
 

 

 

 

 

 

 

                                                                               

 

 

 

     

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SW-10

Page 1: ...injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents Usage of the Product 1 1...

Page 2: ...1 Specifications Nominal Size 20A 100A Application Cold and hot water oil other non dangerous fluids Maximum Pressure 1 0MPa Maximum Temperature 80 Material Body Ductile Cast Iron Cock Stainless stee...

Page 3: ...W 10 SW 10S 20A 200 100 100 126 280 292 363 180 64 5 108 135 248 12 14 R 3 4 23 9 26 7 25A 200 100 100 126 280 292 363 180 64 5 108 135 248 12 14 R 3 4 25 1 27 9 32A 205 102 5 102 5 126 280 292 363 18...

Page 4: ...andard flow velocity depend on the relative kind of fluid Standard flow velocity of fluid Fluid Standard flow velocity Water Oil 2 m s 2 4 The above chart shows the standard flow velocity of relative...

Page 5: ...and cause malfunction 10 Fluid with viscosity stick the parts and lead to malfunction of the products 11 Before connecting the product in the piping be sure to remove foreign substances and scale fro...

Page 6: ...tightened together In this case hit the handle with plastic hammer Do not use iron hammer Turn the adjusting screw clockwise one or two times 2 Fit the pentagon hole of the handle to the cock Stopper...

Page 7: ...side the pipe and remove cover 21 Leakage at outside 1 Gasket O ring 24 is damaged 2 U packing 7 is damaged 1 Replace the gasket and O ring to new one 2 The product need to be disassembled and its par...

Page 8: ...f the screen case and cover Make sure that O ring is attached properly If the O ring is not installed properly O ring may be damaged and can be result in outer leakage 2 In case O ring is damaged or d...

Page 9: ...duct Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by foreign s...