background image

 

1

                                              ■

EPDT-049a

 

1. Overview 

 

The  SY-10  series  strainers  are  widely  used  for  removal  of  foreign  substances  such  as  dust,  pipe 
scale,  chips,  or  slugs  from  various  types  of  pipelines.  Install  this  product  at  the  inlet  side  of  a 
pressure reducing valve, temperature regulating valve, pump, or steam trap. The product has a body 
made  of  cast  carbon  steel  and  a  screen  of  stainless  steel.  Standard  mesh  size  of  the  screen  is  80 
mesh. 
 

 

2.  Features 

 

1.  The product is made of cast carbon steel, with connections of JIS 10K/20K/30K RF flanged and ASME 

Class 150/300 flanged as standard specifications. 

2.  The standard product has a stainless steel screen of 80 mesh with perforation. 

 

3. Specifications 

 

Model 

SY-10-10 

SY-10-20 

SY-10-30 

SY-10-150 

SY-10-300 

Application 

Steam, Air, Cold and hot water, Other non-dangerous fluids   

Nominal size 

15A-250A 

Max. pressure 

1.0 MPa 

2.0 MPa 

3.0 MPa 

1.0 MPa 

2.0 MPa 

Max. temperature 

260°C 

Material 

Body 

Cast carbon steel (SCPH2) 

Cast carbon steel 

(A216 Gr.WCB) 

Screen 

Stainless steel (SUS304) 

Screen 

Perforations 

φ

6 - 8P 

Mesh 

Standard 80 mesh 

Connection 

JIS 10K RF 

flanged 

JIS 20K RF 

flanged 

JIS 30K RF 

flanged 

ASME Class 150 

flanged 

ASME Class 300 

flanged 

 

Available with 20 to 100 mesh filter upon request.

 

 

If the temperature is more than 260 °C, please contact us.

 

 

Summary of Contents for SY-10 Series

Page 1: ...erious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents 1 Overview 1 2 Feat...

Page 2: ...ss 150 300 flanged as standard specifications 2 The standard product has a stainless steel screen of 80 mesh with perforation 3 Specifications Model SY 10 10 SY 10 20 SY 10 30 SY 10 150 SY 10 300 Appl...

Page 3: ...165 56 120 R 1 2 50A 275 170 56 120 R 1 2 65A 300 185 73 125 R 1 2 65A 310 188 73 125 R 1 2 80A 320 210 88 145 R 1 2 80A 345 215 88 145 R 1 2 100A 380 270 108 200 R 1 2 100A 395 275 108 200 R 1 2 125A...

Page 4: ...reases to generate disturbances possibly resulting in pipe wear noise and or vibration If the nominal pipe size is too large not only the costs of piping and equipment but also the thermal loss increa...

Page 5: ...4 EPDT 049a 6 3 Pressure Loss Chart Model SY 10 Strainer Screen 6 8P perforations with 80 mesh filter Nominal size P Pressure loss MPa V Flow rate L min...

Page 6: ...ct shall be installed with its cover faced downward If drainage or similar problem occurs in a steam line incline the product to the position at which the cover is kept horizontally 6 If the product c...

Page 7: ...to the residual pressure 2 After checking the pressure gauge to make certain there is no pressure inside the body 1 remove the cover 2 and screen 3 Clean up the screen 3 by compressed air or water 8...

Page 8: ...improvement without any prior notice After the discontinuation of the product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage d...