69
Lines’ Service Operators
ADM_5_9906_[abcd]
a:
the option that determines the service operators for L1 and L5
b: the option that determines the service operators for L2 and L6
c:
the option that determines the service operators for L3 and L7
d: the option that determines the service operators for L4 and L8.
1= the service operators of four service time periods are specified in
_1,
ADM_4_3, ADM_4_5 and ADM_4_7
2= the service operators of four service time periods are specified in ADM_4_2,
ADM_4_4, ADM_4_6 and ADM_4_8.
Call Pickup Feature Code
ADM_5_9907_[X~]
X~: the feature code that the operating-way specified in
ID DTMF Detection Time
Internal Tone Detection Sensitivity
External Tone Detection Sensitivity
Tone Cycle Filter
ADM_5_9908_[abcd]
a:
the time length between answering a call and starting the main greeting for no ID DTMF
0= 1 second (Default), 1= 1.5 seconds, 2= 2 seconds.
b: the value that raises the sensitivity of internal tone detection
0= 0 (default), 1= +2, 2= +4, 3= +6, 4= +8, 5= +10, 6= +12, 7= +14 db.
c:
the value that raises the tone detection sensitivity on external calls
0= 0 (default), 1= +2, 2= +4, 3= +6, 4= +8, 5= +10, 6= +12, 7= +14 db.
d: the option that determines whether the Tone Cycle filter is used
0= not using the Tone Cycle filter
1~7= the maximum length of silence that is ignored in tone detection
1= 0.03, 2= 0.06, 3= 0.09, 4= 0.12, 5= 0.15, 6= 0.18, 7= 0.21 seconds
For example, if the cycle format of the ring back tone is that "0.4-sec ON, 0.2-sec OFF,
0.4-sec ON" repeats after one second of silence and then repeats after four seconds of
silence, it is necessary to ignore each "0.2-sec OFF" in tone detection because there are
three different tone cycles (a "0.4-sec ON / 0.2-sec OFF", a "0.4-sec ON / 1-sec OFF" and
a "0.4-sec ON / 4-sec OFF").
All the Tone Cycle Length settings should be reset after the Internal Tone Detection sensitivity is
changed.
Internal Path Access Code
ADM_5_9909_[X~]
X~: the number that is dialed before an internal phone number (Default= empty)