Trip Text
Trip
code
Description
Joystick error
-
The most common cause of this error is when the
joystick is not in the center position when the control
system is switched on. The
Joystick displaced
screen is shown for 5 seconds. If the joystick is not
released within this time, the system reports an
error.
•
Make sure that the joystick is in the center
position and re-try to switch on the system.
If the error is still present: the joystick or the joystick
module may need to be replaced.
Low Battery
-
The control system detects that the battery voltage
is below 16V.
•
Check the condition of the batteries and check
the connections to the control system.
If this does not solve the error, the power module
may be defect.
High Battery
-
The control system detects that the battery voltage
is above 35 V. Most common reasons for this are:
overcharging of the batteries or bad connections
between the batteries and the control system.
•
Check the condition of the batteries and check
the connections to the control system.
If this does not solve the error, the power module
may be defect.
M1 Brake Error
1505
The control system detects a problem in the
solenoid brakes of the M1 motor or the connection to
them.
•
Check the solenoid brakes, cables and the
connections to the control system.
If this does not solve the error, the power module
may be defect.
M2 Brake Error
1506
The control system detects a problem in the
solenoid brakes of the M2 motor or the connection to
them.
•
Check the solenoid brakes, cables and the
connections to the control system.
If this does not solve the error, the power
module may be defect.
M1 Motor Error
3B00
The control system detects that this motor has
become disconnected.
•
Check the motor, cables and the connections to
the control system. .
If this does not solve the error, the power module
may be defect
Troubleshooting
Service manual - Luca