T-720 Installation Manual
T-720A: PROGRAMMED AT THE FACTORY FOR AUTO CHANGEOVER
T-720B: PROGRAMMED AT THE FACTORY FOR COOLING ONLY
·
Open the thermostat by pulling on the
bottom side of the front cover
·
Swing open the internal PCB to the left by
pressing the PCB locking tabs
·
Pull out cables 6" from the wall
·
Insert cable in the central hole of the base
·
Align base and mark the location of the two
mounting holes paying particular attention to
orienting the proper side of the base up
·
Install anchors in the wall and insert screws in
mounting holes on each side of the base
·
Gently swing the circuit board back into the
base until the tabs lock it in place