Indoor Data:

Temperature range:

-9.9 to 50°C [+14.2 to +122°F]

Temperature Units Measured:

°C or °F [switch able]

Humidity Range:

20% to 95%

Outdoor Data:

Transmission distance:
(open area)

30m @ 433MHz

Temperature range:

-20 ~ 50°C [-4 ~ +122°F]

Humidity Range:

20% to 99%

Mount:

wall / table

Main Unit Dimensions:

W136x h82x d17 mm

Thermo Sensor Dimensions: 

w62 x h101 x d24 mm

Battery Requirements:

Base Station [indoor]:

2 x AAA batteries 

Sensors [outdoor]:

2 x AAA batteries

Please note:  Batteries are not including

11.

Products and batteries:

Products and batteries should not be disposed of with normal household waste.

According to Directive 2012/19/EU, the device is to be supplied at the end of its useful 

life to a proper disposal. The valuable materials contained in the device are supplied to 

recycling  and  avoid  the  burden  of  the  environment.  Please  take  this  device  to  a 

collection point for electronic waste or a recycling center.

Remove the batteries from the unit before disposing of it and dispose of them separately. 

Consumer  is  legally  obliged  to  dispose  of  used  batteries  at  a  collection  point  for  used 

batteries,  at  a  local  recycling  center  or  at  the  battery  point  of  sale,  for  further  information, 

contact your local waste disposal company or local government.

12: LIABILITY DISCLAIMER: 

• The electrical and electronic wastes contain hazardous substances; Disposal of 
electronic waste in wild country and/or in unauthorized grounds strongly damages 
the environment. 

• Please contact your local and/or regional authorities to retrieve the addresses of 
legal dumping grounds with selective collection. 

Summary of Contents for YC9080

Page 1: ...rd Comfort Icons according to both temp humidity Indoor Outdoor Temperature and Humidity Alert 2 Main Unit Appearance 2 1 Part A LCD A1 Indoor Outdoor Temperature A2 Past 24 hrs Minimum Temperature Record A3 Past 24 hrs Minimum Temperature Record A4 Indoor Outdoor Humidity A5 Past 24 hrs Minimum Humidity Record A6 Past 24 hrs Minimum Humidity Record ...

Page 2: ...y display D4 Battery Compartment D5 Wall Mount Hole D6 RESET button D7 C F button D8 Temperature Probe Plug Jack D9 Stand 2 3 Part C Structure C1 Wall Mount Hole C2 Battery Cover C3 Stand 4 Getting Started 4 1 Main Unit Slide open main unit battery compartment cover C3 Insert 2 x AAA batteries observing polarity and marks Replace main unit battery compartment cover C3 Use a pin to press the RESET ...

Page 3: ...f main unit failed to receive transmission from outdoor thermo sensor in first 3 minutes after the batteries inserted display on the LCD hold SEARCH button B1 for 3 seconds to receive transmission manually RF icon flashes on the LCD 6 2 Temperature Humidity After start up the unit would display indoor Temperature Indoor humidity and Past 24 Hours Indoor Maximum and Minimum Temperature and Humidity...

Page 4: ...to select to activate the alert function for this channel Once ALERT function is activated the icon appears on the LCD When viewing Indoor Channel press ALERT button select to Activate Indoor Temperature Alert function Activate Indoor Humidity Alert function Activate Indoor temp Humidity Alert function Deactivate Alert function for Indoor Temp Humidity Hold ALERT button for 3 seconds to enter Temp...

Page 5: ...5 seconds without any adjustment 6 6 Frost Alert is shown if the outdoor temperature any channel is between 2 C 3 C 7 Low battery The low battery icon will appear at particular channel indicating that thermo sensor unit of the channel is in low battery status The batteries should be replaced 8 Precautions Use a pin to press the reset button B3 if the unit does not work properly Avoid placing the c...

Page 6: ...roper disposal The valuable materials contained in the device are supplied to recycling and avoid the burden of the environment Please take this device to a collection point for electronic waste or a recycling center Remove the batteries from the unit before disposing of it and dispose of them separately Consumer is legally obliged to dispose of used batteries at a collection point for used batter...

Page 7: ...upplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of the temperature Humidity etc This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not...

Reviews: