18
YT-3300/3301 series
The length of pipeline system should not be extremely long. Longer pipeline system
may affect flow rate due to the friction inside of the pipeline.
4.4 Connection
–
Actuator
4.4.1
Single acting actuator – YT-3300
Singe acting type positioner is set to use OUT1 port. OUT1 port should be connected with
supply pressure port from actuator when using single acting type of spring return actuator.
Singe acting linear (left) and rotary (right) type actuator
4.4.2
Double acting actuator – YT-3300
Double acting type positioner is set to use OUT1 and OUT2 port. As input signal increases,
the supply pressure will be supplied through OUT1 port.
Double acting linear (left) and rotary (right) type actuator
4.4.3
Single acting actuator – YT-3301
Single acting linear (left) and rotary (right) type actuator