Recommended wire

For your reference

):

Safe carrying capacity of rubber or plastic insulated wire(1)

specification

mm

nominal cross

section

mm2

Safe carrying capacity

A

BX

BLX

BV

BLV

1*1.13

1

20

18

1*1.37

1.5

25

22

1*1.76

2.5

33

25

30

23

1*2.24

4

42

33

40

30

1*2.73

6

55

42

50

40

7*1.33

10

80

55

75

55

7*1.76

16

105

80

100

75

7*2.12

25

140

105

130

100

7*2.50

35

170

140

160

125

19*1.83

50

225

170

205

150

19*2.14

75

280

225

255

185

19*2.50

95

340

280

320

240

Note

BX(BLX

copper

aluminum

core rubber insulated wire or BV(BLV

copper

aluminum

core PVC plastic insulated wire

widely used in 500V or less than 500V AC and DC power

distribution system. The temperature for the data listed in the above table is 35

the safe

carrying capacity value for the wire on single coved.

Summary of Contents for D119014

Page 1: ......

Page 2: ...ned RS485 communication baud rate 9600 fixed eight data bits even parity check one stop bit RF communication baud rate 9600 fixed eight data bits without parity check one stop bit RF only used for com...

Page 3: ...2 3 Description A relay status B Impulse indication C Turn Page Button Material Case ABS PC Hook ABS material A B C...

Page 4: ...e LCD screen LCD display for present total kWh press button can be used to turn to different pages totally 4 pages Page 1 active power 000000 00 kWh page 2 voltage 000 0 V page 3 current 00 00 A page...

Page 5: ...4 6 Meter Dimensions Height 100mm Width 76mm Depth 65mm Weight 0 3174kg Net 7 Software Connect the meter correctly with power according to connection diagram includes RS485 wire then power on...

Page 6: ...5 7 1 RS485 communication 7 1 1 Open the software see following interface 7 1 2 Choose the serial port baud rate and open the serial port see following interface...

Page 7: ...ss Factory Default 000000000000 and choose the object which need to be operated then click send data as following 7 1 4 When use broadcast address operate meter needs press button on the meter 7 1 5 T...

Page 8: ...d by yourself fixed them in the location which are waiting for installation Push down the clip under the bottom of the meter for a gear see fig 1 Fig 1 Put the meter into the Din rail as per Fig 2 the...

Page 9: ...8 Fig 4 is after installation Fig 4 Making the connection according to the wiring diagram see Fig 5 Fig 5...

Page 10: ...9 After connection use lead sealing to seal terminal cover see Fig 6 Fig 6...

Page 11: ...3 10 80 55 75 55 7 1 76 16 105 80 100 75 7 2 12 25 140 105 130 100 7 2 50 35 170 140 160 125 19 1 83 50 225 170 205 150 19 2 14 75 280 225 255 185 19 2 50 95 340 280 320 240 Note BX BLX copper aluminu...

Page 12: ...d personnel Installation and operation of this equipment described in this manual may only be performed by qualified personal Only people that are authorized to install connect and use this equipment...

Page 13: ...If in doubt don t use the equipment and contact technical staff Mounting of electric appliances must be carried out only by skilled electricians It is imperative to observe the generally applicable sa...

Reviews: