44
storage device gets overheated Set the temperature limit between 55~70 .
B. Alarm Output Setup
This control item is divided in two parts, “
Buzzer Time
” and “
Relay Time
”.
The user can hold
◄ or ► sign on the screen with the mouse to set the
external buzzer time and video loss buzzer time in “
Buzzer Time
” option.
The adjustment value is from
off
to
99
seconds. Moreover, among “
Relay
Time
” option, the user can hold ◄ or ► sign on the screen to set the
external buzzer time and video loss buzzer time. The adjustment value is
from
off
to
99
seconds as well.
The value of Ext. Alarm
Buzzer
/
Relay Time
determines the buzzer / relay
time of both external alarm in and digital input (IP Cam).
C. Alarm Event Setup
There are eight types of events that can be selected. When the selected
items occur and trigger, events will be recorded in the log and able to be