background image

 

Integrity of body parts; condition of fastening screws and nuts - if rust appears wipe them with 
a alcohol gasoline blend and lubricate with gun oil.  

 

Check that the scope is firmly attached to the rifle.  

 

Objective lens, eyepiece and IR illuminator condition; cracks, finger marks, dirt, water drops 
and other stains are not acceptable.  

 

Make sure not to use depleted batteries or batteries that show stains of electrolyte, salt or acid 
leaks; these conditions may result in damage to the scope. 

 

Check that the power switches (3) and the reticle brightness knob (4) are functioning normally.  

 

Check that the objective lens ring (6) and the eyepiece ring (7) are movable.   

 

MAINTENANCE 
 

It is recommended that technical maintenance should be performed on the Sentinel G2+ at least 2 
times a year; tasks for technical maintenance include:  

 

To clean the exterior of the scope of dust, dirt and moisture using a dry tissue with a few drops 
of gun oil or similar substance applied.  

 

To clean the electrical contact lead located in the battery housing using pure alcohol.  

 

To examine the lenses of the eyepiece, objective lens and IR illuminator and blow off sizable 
particles of sand and dust; clean the lenses only if necessary.  

 

Do not pour liquids directly onto the lens surface when cleaning; apply solution to a clean, dry 
cloth and then proceed to clean the lens.  

 

WARNING: Please use extreme caution when handling hazardous substances, such as 

alcohol. 

 

THE SENTINEL G2+ MAGNIFIER LENS 2.5x50  
 

The NVRS magnifier lens attachment accessory (#29091) helps increase magnification of the Sentinel 
G2+ with an objective lens diameter of 50mm up to 1.75 times. Screw the magnifier lens onto the 
objective lens of the scope according to the instruction manual for the “NVRS 2.5x50 Doubler”. Sight 
in the scope after the magnifier lens is attached due to movement of the reticle. 
 

ADDITIONAL WEAVER MIL-STD-1913 RAILS  
 

The Sentinel G2+ has an additional Weaver rail (12) on the left side of the body. With the help of this 
mount it is possible to install: 

 

The Yukon IR Flashlight with mount (# 29072); 

 

The Yukon Directional Microphone with NVRS adapter (# 27022). 

 

STORAGE  
 

Always store the Sentinel G2+ in its case in a dry well-ventilated and well-heated room away from 
heating/air conditioning vents. Remove the battery if the device is to be stored longer than two 
months. 
 

TROUBLESHOOTING  
 

Listed below are some potential problems that may occur when using the Sentinel G2+. Carry out the 
recommended checks and troubleshooting steps in the order listed. Please note that the table does not 
list all of the possible problems. If the problem experienced with the scope is not mentioned, or if the 
suggested action meant to correct it does not resolve the problem, please contact the manufacturer. 
 

Summary of Contents for 26125T

Page 1: ...djustment IPX4 rating against water intrusion Precision internal windage elevation adjustment Ergonomic design Quick power up Vertical positioning of the battery ensures uninterrupted power supply whe...

Page 2: ...r use with cartridges producing recoil rating higher than 6000 joules or calibers in excess of 9 375 The manufacturer s warranty will be voided if damage is caused by caliber cartridges greater than 9...

Page 3: ...ions or at night time Install the batteries according to the directions in the section entitled BATTERY INSTALLATION Enter a dark environment Remove the objective lens cap by sliding it up on top of t...

Page 4: ...n the ON or OFF position the IR illuminator will not have any effect in a lighted environment Note The sighting of the scope should be performed under the same environmental and temperature conditions...

Page 5: ...cle the target is 25 meters 27 yards away Please see a drawing below VERTICAL SCALE The four short horizontal bars are located on the main vertical line If a 0 35 meter 13 7 inch high target fits betw...

Page 6: ...Range in Meters Object s Width or Height in Mils Example 1 33 yards x 1000 2 5 mils 532 Yards When making windage elevation adjustments please note that one click of the riflescope s adjustment equals...

Page 7: ...ply solution to a clean dry cloth and then proceed to clean the lens WARNING Please use extreme caution when handling hazardous substances such as alcohol THE SENTINEL G2 MAGNIFIER LENS 2 5x50 The NVR...

Page 8: ...g it in a warm environment for 4 hours Total battery charge is less than 2 0V Install fresh batteries With a crisp reticle image the image of the target at least 30m away is blurred Luminance level in...

Page 9: ...cording to the instructions in the OPERATING THE SENTINEL G2 section and check the eyepiece and objective lens condition if necessary clean the lenses of dirt dust condensation frost etc to prevent fo...