background image

 

The scope has been reinforced with an IPX6 rating against water intrusion and can be used in 
inclement weather; however, it is not intended for full submersion.  

 

Attempting to disassemble or repair the scope will void the warranty! 

 

Clean the scope's optical surfaces only if necessary, and use caution. First, remove (by blowing 
or carefully wiping off) any dust or sand particles. Then proceed to clean by using a soft cotton 
tissue and alcohol or a cleaning solution approved for use with multicoated lenses. Do not pour 
the solution directly onto the lens! 

 

The scope can be used in operating temperatures, ranging from -30°C to +40°C. However, if it 
has been brought indoors from cold temperatures, do not turn it on for 3 to 4 hours. 

 

If the riflescope is unable to mount onto the rifle securely, or if there are doubts about the 
mounting system, see a qualified gunsmith. Using the weapon with a poorly mounted scope can 
lead to inaccurate target shooting! 

 

To ensure reliable performance, it is recommended to carry out regular technical inspections of 
the unit. 

 

 

 
BATTERY INSTALLATION 
 

 

Unscrew the cap (1) of the battery compartment counter-clockwise  

 

Install one AA (1.5V) or CR 123 (3V) battery, so that the (+) and (-) match the markings on the 
body of the unit 

 

Tighten the cap (1) 

 

OPERATING THE PHANTOM 
 

 

Install the batteries according to the directions in the section entitled “BATTERY 
INSTALLATION” 

 

Enter a dark environment 

 

Remove the objective lens cap by sliding it up on top of the objective lens (2) 

 

Turn on the unit by turning the selector switch (3) to the “ON” position; you will see the 
screen of the electronic-optical converter light up green  

 

The scope can also be checked in an illuminated area, but this is meant solely for testing the 
device; the lens cap (2) must tightly cover the objective lens  

 

To adjust the brightness of the red reticle, turn knob (4)  

 

To select one of the five (three - if EPM66G tube employed) types of red reticles, press button 
(5) 

 

Choose a removed stationary object to observe, at a distance of about 100 m 

 

Turn the focusing knob (6) to “100”, it will settle into a notch 

Summary of Contents for PHANTOM 26057T

Page 1: ...f heavy recoil ammunition 375 H H 416 Rigby 50 cal Vertical positioning of the battery ensures an uninterrupted power supply when firing The image intensifier tube is protected against excessive light exposure Incremental reticle brightness adjustment The reticle will blink as a warning 15 30 minutes before the device shuts down automatically as a low battery indicator Stabilized power supply for ...

Page 2: ... and hunting Patrolling and safeguarding Search and rescue GUIDELINES FOR OPERATION The PHANTOM has been designed for extensive usage To ensure longevity and performance it is necessary to adhere to the following Under illuminated conditions measuring more than 1 lux deep dusk do not power on the riflescope with the objective lens cap open and do not point the product towards a direct light source...

Page 3: ...target shooting To ensure reliable performance it is recommended to carry out regular technical inspections of the unit BATTERY INSTALLATION Unscrew the cap 1 of the battery compartment counter clockwise Install one AA 1 5V or CR 123 3V battery so that the and match the markings on the body of the unit Tighten the cap 1 OPERATING THE PHANTOM Install the batteries according to the directions in the...

Page 4: ... be turned on instantaneously with either the remote control housed in its bracket 10 or by button 11 SIGHTING IN THE PHANTOM Sighting in of the scope should be done at operating temperatures by following the order of these steps Mount the rifle with the scope installed on a scoped machine Make sure that no sources of light are visible through the scope s field of vision Set a target at a distance...

Page 5: ...he battery makes contact with metal Verify the proper function of the following selector switch 3 reticle brightness knob 4 reticle selector button and the instant power on button 11 Verify the smoothness of the objective lens focusing mechanism 6 diopter focusing knob 7 and the IR illuminator knob 8 TECHNICAL MAINTENANCE Technical maintenance should be done no less than twice a year and is compri...

Page 6: ...e diopter cannot be adjusted to your vision If you wear prescription glasses with a range of 5 keep glasses on when looking through the eyepiece Dust and moisture are covering the outside optical surfaces Clean the lens surfaces with a soft cotton tissue or cloth Moisture is on the inside of the objective and the eyepiece lenses or is on the optical surfaces of the electronic optical converter and...

Page 7: ... sighted in during the summer and is now being used in the winter or the other way around a small displacement of the aiming point is possible The scope does not focus Wrong settings Adjust the riflescope according to the instructions given in the section entitled OPERATING THE PHANTOM and check the surfaces of the eyepiece and objective lenses and clean them if necessary from dust condensation fr...