Instruction Manual, Toftejorg SaniMidget Retractor
Page 15
IM-TE91A750-EN1
Maintenance and repair
(continued)
Check/Inspection
1. Check the cleaner head for wear and remove possible particles. Look for any damage of the slide
bearings of the cleaner head and on the valve and piston. Replace new parts and cleaner head if
necessary.
2. Check o-ring on valve and piston for wear and replace if necessary.
Reassembly
Reassembly is carried out in the opposite order.
Rear part Media driven
Alfa Laval Tank Equipment A/S
do not recommend or support disassembly of the rear part in the field.
Please return the machine to us for disassembly.
Rear Part Pneumatic driven
Alfa Laval Tank Equipment A/S do not recommend or support disassembly of the rear part in the field.
Please return the machine to us for disassembly.