Revised 03-11-10
YUNCA FUZiON FEBRUARY 2010
Page 13 of 19
MAINTENANCE
(cont).
WARNING: The following procedures should be performed only by a qualified service person.
The gas supply and electrical power should be isolated whenever any maintenance
procedures are undertaken.
CLEANING THE LOG SET AND FIREBOX
.
During the annual inspection and maintenance appointment,
the service person
should clean dust
lint and any light soot accumulation from the logs and the fire box area. An extra soft brush should
be used on the logs, as they are extremely fragile. If at any time the logs cannot be removed or
installed without force, the cause must be found. The logs must never be forced.
Procedure:
1. Remove Front Door as described on page 11.
2. Remove the complete log set from the firebox by lifting it up and out. Brush it gently over a
newspaper and carefully place it out of the way.
3. The bark tray can be removed by undoing the attachment screws and lifting out.
4. With firebox empty, a vacuum cleaner can be used to remove any visible dust and lint from within
the firebox area.
5. Replace the bark tray.
6. Replace log set.
7. Replace the front door.
CLEANING UNDER THE TOP AND LOUVRES
Two screws at the back and two lugs at the front hold the top panel in place. Remove the screws.
Lift the top up and slide forward to disengage the front lugs. Move the top to allow the access to
clean.
Note:
If a flue guard kit has been fitted this will need to be removed at this stage. This is done by
sliding the front half up and out and unscrewing the back half from its brackets.
INSPECTING THE VENTING
An inspection of the venting system should be made during the annual service appointment. There
must be no blockages and the flue must be in good repair. Any sections that are taken apart for
inspection must be reassembled and sealed as required.
FIG 5
GAS CONTROL VALVE
CONNECTIONS