Revised 03-11-10
YUNCA FUZiON FEBRUARY 2010
Page 14 of 19
MAINTENANCE
(cont)
HOW TO REMOVE FAN
(Fig 6)
NOTE. Disconnect Main Power first
1. Remove the Door and Top Louvre. ( see page 11)
2. Remove 3 screws holding Hearth.
3. Unplug White connector Block.
4. Disconnect EARTH Wire from Control Valve Bracket.
5. Unscrew 2
nd
EARTH Wire from Hearth.
6. Loosen 4 screws holding Fan to the Back Panel (keyhole slots)
7. Remove Fan
Back Panel
Fan
Screws
Hearth